Tunable aptamer-MXene sensing interface for label-free and real-time detection of toxic pollutants in water samples.

Biosens Bioelectron

Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian, 116024, China.

Published: December 2024

Stable and low-cost field-effect transistor (FET)-based biosensors are vital for the on-site detection of toxic pollutants in environmental monitoring applications. In this study, a tunable aptamer-MXene sensing interface was constructed to develop renewable FET biosensors. This was achieved through the reversible disulfide bond (-S-S-) reaction between the SH-TiCT film and thiolated aptamer. TiCT film was prepared using layer-by-layer assembly of TiCT flakes and used as the conductance channel of this FET device. Then, dithiothreitol modification was carried out through the formation of Ti-S bonds. The reversible -S-S- bonds enabled the repeated regeneration of SH-TiCT, which allowed deferent aptamers to be immobilized. Therefore, multiple targets could be detected with the same FET device, avoiding device-to-device variations. Three specific aptamers for microcystin-LR, β-lactam-resistant gene (β-ARG), and Hg were adopted to demonstrate this characteristic. The prepared aptamer-MXene FET biosensor showed high sensitivity, repeatability and stability. Furthermore, a strong real-time response was observed upon exposure to the targets. This study demonstrated that constructing a tunable aptamer-MXene sensing interface is an efficient strategy for constructing cheap and renewable aptamer-MXene FET biosensors for the label-free and real-time detection of toxic pollutants.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2024.117096DOI Listing

Publication Analysis

Top Keywords

tunable aptamer-mxene
12
aptamer-mxene sensing
12
sensing interface
12
detection toxic
12
toxic pollutants
12
label-free real-time
8
real-time detection
8
fet biosensors
8
fet device
8
aptamer-mxene fet
8

Similar Publications

Tunable aptamer-MXene sensing interface for label-free and real-time detection of toxic pollutants in water samples.

Biosens Bioelectron

December 2024

Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian, 116024, China.

Stable and low-cost field-effect transistor (FET)-based biosensors are vital for the on-site detection of toxic pollutants in environmental monitoring applications. In this study, a tunable aptamer-MXene sensing interface was constructed to develop renewable FET biosensors. This was achieved through the reversible disulfide bond (-S-S-) reaction between the SH-TiCT film and thiolated aptamer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!