Immediate breast reconstruction provides breast cancer patients with a valuable opportunity to restore breast shape. However, post-reconstruction breast asymmetry remains a common issue that affects patient satisfaction. This study aims to quantify breast asymmetry after surgery using magnetic resonance imaging (MRI) and assess its impact on both breast satisfaction and overall outcome satisfaction, offering scientific evidence to guide improvements in preoperative evaluation. We retrospectively collected MRI images and demographic characteristics from 98 patients who underwent unilateral immediate breast reconstruction. All patients underwent breast MRI scans post-reconstruction, and the MRI images were converted into 3D models using 3D Slicer software. The implant volumes were measured and compared with the actual implant volumes inserted during surgery to assess the accuracy of the MRI measurements. Breast symmetry after surgery was quantified using MRI-measured breast volumes, and patient satisfaction was analyzed through BREAST-Q questionnaires to explore the relationship between breast symmetry, post-reconstruction breast satisfaction, and overall outcome satisfaction. The implant volumes measured in the 3D reconstructed MRI images exhibited high concordance with the volumes recorded during surgery (r = 0.980, p < 0.001). Breast asymmetry values were significantly higher in the high BMI group compared to the low BMI group (P = 0.013), while the asymmetry ratio was significantly lower in the high weight group compared to the low weight group (P = 0.006). The asymmetry ratio showed a weak correlation with breast satisfaction (r = - 0.341, P = 0.002) and outcome satisfaction (r = - 0.371, P = 0.004). When grouped by low asymmetry (asymmetry > 10%), there was no significant difference in breast satisfaction (P = 0.054) or outcome satisfaction scores (P = 0.23) between the groups. However, in cases of high asymmetry (asymmetry ratio > 40%), breast satisfaction (P = 0.003) and outcome satisfaction scores (P = 0.005) were significantly lower in the asymmetry group compared to the symmetry group. Breast volume asymmetry after immediate breast reconstruction is associated with patient satisfaction, with a significant decrease in satisfaction when asymmetry exceeds 40%. This suggests that preoperative evaluation should focus on breast symmetry to improve post-reconstruction patient satisfaction and surgical outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1038/s41598-024-80522-yDOI Listing

Publication Analysis

Top Keywords

breast
20
patient satisfaction
20
breast reconstruction
16
breast satisfaction
16
outcome satisfaction
16
satisfaction
14
mri images
12
implant volumes
12
breast symmetry
12
breast volume
8

Similar Publications

Ultrasound-responsive nanoparticles for nitric oxide release to inhibit the growth of breast cancer.

Cancer Cell Int

December 2024

Department of Ultrasound, Chongqing General Hospital, Chongqing University, Chongqing, 401147, China.

Gas therapy represents a promising strategy for cancer treatment, with nitric oxide (NO) therapy showing particular potential in tumor therapy. However, ensuring sufficient production of NO remains a significant challenge. Leveraging ultrasound-responsive nanoparticles to promote the release of NO is an emerging way to solve this challenge.

View Article and Find Full Text PDF

Background: Exclusive breastfeeding (EBF) is defined as feeding infants only breast milk of the mother or a wet nurse for the first six months, without additional food or liquids except the oral rehydration solution or drops/syrups of vitamins, minerals or medicines. The working status of women in developed countries adversely affects the EBF rates, which calls for an assessment in rapidly developing countries like India. Therefore, the primary aim of the present study is to determine the prevalence of EBF using the data from the National Family Health Surveys (NFHS 3, 4, 5) conducted between 2005 and 06, 2015-16 and 2019-21 to estimate the likelihood EBF according to mothers' employment status.

View Article and Find Full Text PDF

Targeting CDK2 to circumvent treatment resistance in HR breast cancer.

Trends Mol Med

December 2024

Cancer Signaling and Microenvironment Program, Fox Chase Cancer Center, Philadelphia, PA, USA. Electronic address:

Genetic and epigenetic defects of the p53 system have previously been associated with resistance to CDK4/6 inhibitors in women with HR breast cancer. Recent data from Kudo et al. demonstrate that CDK2-targeting agents may offer an effective strategy to circumvent such resistance by enforcing cellular senescence downstream of RBL2 dephosphorylation.

View Article and Find Full Text PDF

Dabrafenib upregulates hypoglycosylated MUC1 and improves the therapeutic efficacy of Tn-MUC1 CAR-T cells.

Sci Bull (Beijing)

December 2024

Breast Cancer Center, Zhejiang Cancer Hospital, Hangzhou Institute of Medicine (HIM), Chinese Academy of Sciences, Hangzhou, Zhejiang 310022, China. Electronic address:

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!