LieRHRV system for remote lie detection using heart rate variability parameters.

Sci Rep

Laboratory of Bioelectric and Bioenergetic Systems, Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, Israel.

Published: December 2024

The standard polygraph, or lie detector, is limited by its reliance on average heart rate, subjective examiner interpretation, and the need for direct subject contact. Remote photoplethysmography (rPPG) offers a promising contactless alternative, by using facial videos to extract heart rate variability (HRV). We introduce "LieRHRV," a remote lie detection algorithm based solely on extracted HRV parameters. To test the HRV parameter quality, we compared these parameters to HRV parameters extracted from ECG and photoplethysmography (PPG) records archived in five gold-standard ECG/PPG datasets. A prospective study of 39 healthy volunteers was also performed to evaluate the accuracy of lie detection based on PPG- or rPPG-derived HRV parameters. Effective HRV parameter extraction from both PPG and ECG sources was demonstrated, with comparable outcomes among 60% of the parameters on average with the publicly available datasets, and prospective study with 80% of the parameters. LieRHRV performance on ECG, PPG or rPPG (with parameters selected for PPG) exhibited an accuracy of 83.3 ± 3%, 87.3 ± 4% or 91.7 ± 3.5%, respectively. In comparison, the naïve model for ECG, PPG or rPPG data achieved an accuracy of 58.3 ± 3%, 61.0 ± 3% or 67.0 ± 5%, respectively. This study demonstrated the feasibility and effectiveness of LieRHRV, and offers a promising avenue for advancing lie detection technologies beyond polygraph limitations.

Download full-text PDF

Source
http://dx.doi.org/10.1038/s41598-024-80480-5DOI Listing

Publication Analysis

Top Keywords

lie detection
16
heart rate
12
hrv parameters
12
remote lie
8
rate variability
8
parameters
8
offers promising
8
hrv parameter
8
datasets prospective
8
prospective study
8

Similar Publications

LieRHRV system for remote lie detection using heart rate variability parameters.

Sci Rep

December 2024

Laboratory of Bioelectric and Bioenergetic Systems, Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, Israel.

The standard polygraph, or lie detector, is limited by its reliance on average heart rate, subjective examiner interpretation, and the need for direct subject contact. Remote photoplethysmography (rPPG) offers a promising contactless alternative, by using facial videos to extract heart rate variability (HRV). We introduce "LieRHRV," a remote lie detection algorithm based solely on extracted HRV parameters.

View Article and Find Full Text PDF

Coronary computed tomography angiography (CCTA) is a powerful tool to rule out coronary artery disease (CAD). In the last decade, myocardial perfusion CT (CTP) technique has been developed for the evaluation of myocardial ischemia, thereby increasing positive predictive value for diagnosis of obstructive CAD. A diagnostic strategy combining CCTA and perfusion acquisitions provides both anatomical coronary evaluation and functional evaluation of the stenosis, increasing the specificity and the positive predictive value of cardiac CT.

View Article and Find Full Text PDF

Gynecological inflammations have a significant impact on the daily lives of women. Meanwhile, cancers such as ovarian, cervical, and endometrial cancers pose severe threats to their physical and mental well-being. While current options such as conventional pharmacotherapy, surgical interventions, and recent advancements in immunotherapy and targeted therapy provide viable solutions, they possess limitations in effectively addressing the intricacies associated with gynecological diseases.

View Article and Find Full Text PDF

Psychophysiological indexes in the detection of deception: A systematic review.

Acta Psychol (Amst)

November 2024

Faculty of Medicine and Psychology, "Sapienza", University of Rome, Rome, Italy; Department of Psychology, University of Hull, Hull, United Kingdom.

Robust evidence on deception detection highlights that humans perform at chance level, especially when a truth-default cognitive threshold is crossed by the deceiver. This systematic review examined whether identification of deceptive stimuli elicits specific physiological responses in the detectors of deception. Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, five databases were searched for human studies that evaluate physiological reactivity to deceptive stimuli, along with behavioural responses.

View Article and Find Full Text PDF

Deception is a universal human behavior. Yet longstanding skepticism about the validity of measures used to characterize the biological mechanisms underlying deceptive behavior has relegated such studies to the scientific periphery. Here, we address these fundamental questions by applying machine learning methods and functional magnetic resonance imaging (fMRI) to signaling games capturing motivated deception in human participants.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!