Fully Navigated Single-Position Prone Lateral Lumbar Interbody Fusion: A Detailed Technical Report and Description of 15 Cases.

Int J Spine Surg

Spine Team, Division of Orthopedic Surgery and Musculoskeletal Trauma Care, Geneva University Hospitals, Faculty of Medecine, University of Geneva, Geneva, Switzerland

Published: December 2024

Background: Navigation increases the precision and safety of pedicle screw placement and has been used to place interbody cages for lateral lumbar interbody fusion. Single-position surgery shortens its duration and that of anesthesia. The aim of this study was the feasibility of simultaneous cage and screw placement in a single prone position using intraoperative navigation without the need for additional fluoroscopy and a detailed technical description of this procedure.

Methods: We retrospectively analyzed 15 patients who underwent simultaneous navigated lateral lumbar interbody fusion and posterior instrumentation in a single prone position. A detailed technical description of the procedure is provided. Surgery duration, blood loss, complications, and radiographic parameters were recorded.

Results: A total of 24 cages were placed in 15 patients. The mean time taken for cage placement was 21 ± 6.70 minutes, and there were no major complications. Mean surgery duration and blood loss per case, including posterior instrumentation, were 263 ± 94 minutes and 315 ± 143 mL, respectively. There were significant improvements in pre- to postoperative Oswestry Disability Index scores (51.38 ± 15.93 vs 32.81 ± 17.18, < 0.001) and segmental lordosis (3.26° ± 8.97° vs 13.09° ± 15.25°, < 0.001).

Conclusion: The present study's results showed the feasibility of lateral lumbar interbody fusion using simultaneous posterior pedicle screw instrumentation and intraoperative navigation in a single prone position.

Clinical Relevance: Navigated lateral lumbar interbody fusion and posterior instrumentation in a single prone position possibly reduces operating time and blood loss and reduces exposure of operation room personnel to radiation.

Download full-text PDF

Source
http://dx.doi.org/10.14444/8697DOI Listing

Publication Analysis

Top Keywords

lateral lumbar
20
lumbar interbody
20
interbody fusion
20
single prone
16
detailed technical
12
prone position
12
posterior instrumentation
12
blood loss
12
pedicle screw
8
screw placement
8

Similar Publications

Fully Navigated Single-Position Prone Lateral Lumbar Interbody Fusion: A Detailed Technical Report and Description of 15 Cases.

Int J Spine Surg

December 2024

Spine Team, Division of Orthopedic Surgery and Musculoskeletal Trauma Care, Geneva University Hospitals, Faculty of Medecine, University of Geneva, Geneva, Switzerland

Background: Navigation increases the precision and safety of pedicle screw placement and has been used to place interbody cages for lateral lumbar interbody fusion. Single-position surgery shortens its duration and that of anesthesia. The aim of this study was the feasibility of simultaneous cage and screw placement in a single prone position using intraoperative navigation without the need for additional fluoroscopy and a detailed technical description of this procedure.

View Article and Find Full Text PDF

Spine Kinematics Behavior During the Handstand Posture: A Biplanar Radiographic Analysis.

J Funct Morphol Kinesiol

December 2024

Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers Sciences and Technologies, 75013 Paris, France.

The handstand is an exercise performed in many sports, either for its own sake or as part of physical training. Unlike the upright bipedal standing posture, little is known about the sagittal alignment and balance of the spine during a handstand, which may hinder coaching and reduce the benefits of this exercise if not performed correctly. The purpose of this study was to quantify the sagittal alignment and balance of the spine during a handstand using radiographic images to characterize the strategies employed by the spino-pelvic complex during this posture.

View Article and Find Full Text PDF

: Instability is a major reason for revision after total hip arthroplasty (THA), and acetabular cup placement in the "traditional" safe zone does not protect against dislocations. Spinopelvic mobility may play a role in impingement and dislocation after THA. Personalized acetabular cup placement that incorporates spinopelvic mobility is currently lacking in the literature.

View Article and Find Full Text PDF

Objectives: Glucocorticoid cosecretion is more common in primary aldosteronism (PA) than previously thought. Chronic subtle cortisol excess in patients with mild autonomous cortisol secretion (MACS) negatively affects bone health. This study aimed to evaluate the impact of MACS on bone density and turnover markers in PA patients.

View Article and Find Full Text PDF

Objective: This study aims to introduce a two-stage surgical procedure, namely oblique lateral interbody fusion (OLIF), for spinal disorders treatment. Furthermore, clinical outcomes and imaging results are analyzed between OLIF with posterior fixation and posterior lumbar interbody fusion (PLIF) with fixation for lumbosacral curve-driven degenerative lumbar scoliosis (DLS).

Methods: 146 patients with type 2 DLS who underwent OLIF or PLIF between January 2019 and November 2023 were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!