Background: Dark-field radiography has been proven to be a promising tool for the assessment of various lung diseases.

Purpose: To evaluate the potential of dose reduction in dark-field chest radiography for the detection of the Coronavirus SARS-CoV-2 (COVID-19) pneumonia.

Materials And Methods: Patients aged at least 18 years with a medically indicated chest computed tomography scan (CT scan) were screened for participation in a prospective study between October 2018 and December 2020. Patients were included if they had a CO-RADS (COVID-19 Reporting and Data System) score ≥ 4 (COVID-19 group) or if they had no pathologic lung changes (controls). A total of 89 participants with a median age of 60 years (interquartile range 48 to 68 yrs.) were included in this study. Dark-field and attenuation-based radiographs were simultaneously obtained by using a prototype system for dark-field radiography. By modifying the image reconstruction algorithm, low-dose radiographs were simulated based on real participant images. The simulated radiographs corresponded to 50%, 25%, and 13% of the full dose (41.9 μSv, median value). Four experienced radiologists served as blinded readers assessing both image modalities, displayed side by side in random order. The presence of COVID-19-associated lung changes was rated on a scale from 1 to 6. The readers' diagnostic performance was evaluated by analyzing the area under the receiver operating characteristic curves (AUC) using Obuchowski's method. Also, the dark-field images were analyzed quantitatively by comparing the dark-field coefficients within and between the COVID-19 and the control group.

Results: The readers' diagnostic performance in the image evaluation, as described by the AUC value (where a value of 1 corresponds to perfect diagnostic accuracy), did not differ significantly between the full dose images (AUC = 0.86) and the simulated images at 50% (AUC = 0.86) and 25% of the full dose(AUC = 0.84) (p>0.050), but was slightly lower at 13% dose (AUC = 0.82) (p = 0.038). For all four radiation dose levels, the median dark-field coefficients within groups were identical but different significantly by 15% between the controls and the COVID-19 pneumonia group (p<0.001).

Conclusion: Dark-field imaging can be used to diagnose the Coronavirus SARS-CoV-2 (COVID-19) pneumonia with a median dose of 10.5 μSv, which corresponds to 25% of the original dose used for dark-field chest imaging.

Download full-text PDF

Source
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0316104PLOS

Publication Analysis

Top Keywords

dark-field radiography
12
dark-field
8
radiography detection
8
covid-19 pneumonia
8
lung changes
8
full dose
8
readers' diagnostic
8
diagnostic performance
8
dark-field coefficients
8
auc 086
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!