In same-day radioembolization, 99mTc-MAA SPECT/CT, 90Y radioembolization, and post-treatment 90Y SPECT/CT procedures are conducted on the same-day, resulting in a dual-isotope environment of 90Y and 99mTc during post-treatment imaging. This study aimed to quantify the impact of 99mTc on 90Y bremsstrahlung-SPECT/CT image quality and to establish an optimised imaging protocol for both clinical practice, and with advanced reconstruction techniques. Utilising a NEMA IQ phantom, contrast recovery coefficients (CRCs) were measured to evaluate the 90Y image quality degradation caused by 99mTc. SPECT/CT scans of 90Y-only and 90Y with varying amounts of 99mTc were conducted using a standard protocol (90-120 keV energy window, high-energy collimator) and various dual-isotope protocols. The standard protocol resulted in a marked CRC reduction, with the largest sphere's CRC decreasing from 0.21 (90Y-only) to 0.05 when 99mTc activity was 5% of 90Y. For an optimised protocol (160-200 keV energy window, high-energy collimator) CRC values were 0.16 for 90Y-only and 0.15 for 90Y+99mTc. The highest CRC values were achieved with an advanced Monte Carlo-based reconstruction, showing 0.58 for 90Y-only and 0.46 for 90Y+99mTc. Image quality degradation was noted in dual-isotope settings even when using an optimised protocol. Advanced reconstruction techniques markedly improved post-treatment image quality.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3390/curroncol31120554 | DOI Listing |
Invest Radiol
October 2024
From the Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich, Zurich, Switzerland (B.K., F.E., J.K., T.F., L.J.); Advanced Radiology Center, Department of Diagnostic Imaging and Oncological Radiotherapy, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy (C.S., A.R.L.); and Section of Radiology, Department of Radiological and Hematological Sciences, Università Cattolica del Sacro Cuore, Rome, Italy (A.R.L.).
Objectives: The aim of this study was to evaluate the feasibility and efficacy of visual scoring, low-attenuation volume (LAV), and deep learning methods for estimating emphysema extent in x-ray dose photon-counting detector computed tomography (PCD-CT), aiming to explore future dose reduction potentials.
Methods: One hundred one prospectively enrolled patients underwent noncontrast low- and chest x-ray dose CT scans in the same study using PCD-CT. Overall image quality, sharpness, and noise, as well as visual emphysema pattern (no, trace, mild, moderate, confluent, and advanced destructive emphysema; as defined by the Fleischner Society), were independently assessed by 2 experienced radiologists for low- and x-ray dose images, followed by an expert consensus read.
Curr Opin Otolaryngol Head Neck Surg
October 2024
Department of Otolaryngology - Head & Neck Surgery, University of Florida, Gainesville, Florida, USA.
Purpose Of Review: Fibro-osseous lesions (FOL) are benign, slow-growing lesions that are often incidentally discovered in the sinonasal cavity. They may necessitate surgical resection in patients with postobstructive sinusitis, or in cases of cranial nerve and orbital compression. We examine the recent advancements in otolaryngology relating to diagnostic characteristics and treatments for FOL, with emphasis on new technologies to improve outcomes and reduce recurrence.
View Article and Find Full Text PDFMed Phys
December 2024
School of Physics and Optoelectronic Engineering, Foshan University, Foshan, China.
Background: In clinical practices, doctors usually need to synthesize several single-modality medical images for diagnosis, which is a time-consuming and costly process. With this background, multimodal medical image fusion (MMIF) techniques have emerged to synthesize medical images of different modalities, providing a comprehensive and objective interpretation of the lesion.
Purpose: Although existing MMIF approaches have shown promising results, they often overlook the importance of multiscale feature diversity and attention interaction, which are essential for superior visual outcomes.
Med Phys
December 2024
Department of Physics, Lakehead University, Thunder Bay, Ontario, Canada.
Background: This study investigates a multi-angle acquisition method aimed at improving image quality in organ-targeted PET detectors with planar detector heads. Organ-targeted PET technologies have emerged to address limitations of conventional whole-body PET/CT systems, such as restricted axial field-of-view (AFOV), limited spatial resolution, and high radiation exposure associated with PET procedures. The AFOV in organ-targeted PET can be adjusted to the organ of interest, minimizing unwanted signals from other parts of the body, thus improving signal collection efficiency and reducing the dose of administered radiotracer.
View Article and Find Full Text PDFJ Xray Sci Technol
December 2024
School of Electrical and Information Engineering, Tianjin University, Nankai District, Tianjin, China.
Background: Airport security is still a main concern for assuring passenger safety and stopping illegal activity. Dual-energy X-ray Imaging (DEXI) is one of the most important technologies for detecting hidden items in passenger luggage. However, noise in DEXI images, arising from various sources such as electronic interference and fluctuations in X-ray intensity, can compromise the effectiveness of object identification.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!