Routine serum studies in a female patient with sustained prediabetic glycated hemoglobin A (HbA) levels, controlled on metformin, yielded an unexpected finding: an elevated HbA value of ≥14.9% (≥139 mmol/mol) (normal reference range, <5.7% to <39 mmol/mol). Estimated average glucose (EAG) (normal reference range, <126 mg/dL to <7 mmol/L) is a linearly corresponding blood glucose value calculated from HbA measurements that reflects the average glycemic status over the preceding 3 months. Caution must be used when the EAG provided by the HbA does not align with blood glucose values obtained around the same period. Our patient carries a rare heterozygous pathogenic variant affecting the β subunit called hemoglobin Graz (Hb Graz), characterized by a histidine for leucine substitution, resulting in clinically silent Hb abnormalities. Individuals without diabetes carrying the Hb Graz pathogenic variant exhibit significantly higher HbA values when analyzed by high-performance liquid chromatography. Alternative methods of quantifying glycemic control are suggested if the possibility of a confounding variable exists, such as when a HbA-blood glucose mismatch occurs or unexplainable HbA levels are detected.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11669862 | PMC |
http://dx.doi.org/10.1210/jcemcr/luae242 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!