Comparison of radiographic imaging quality/accuracy using photostimulable phosphor plates and metal oxide semiconductor receptors.

J Dent Educ

Instituto de Odontoestomatología, Escuela de Odontología, Facultad de Medicina, Universidad Austral de Chile, Valdivia, Chile.

Published: December 2024

Aim: To compare thequality and accuracy of radiographic images obtained by dentistry students from a Chilean university using photostimulable phosphor plates (PSP) and complementary metal oxide semiconductor (CMOS) receptors.

Materials And Methods: An experimental study was carried out in which 31 dental students used PSP and CMOS receptors to acquire radiographic images with the aid of a phantom. The time required to generate a radiograph was recorded. Image quality included sharpness/definition and brightness/contrast analysis. Accuracy assessed placement error, angulation errors, and cone cutting. A three-point scale was used for each variable: 0 = undiagnosable, 1 = acceptable diagnosis with minor errors, and 2 = perfect diagnostic quality.

Results: The required time to generate a radiograph was faster with PSP than with CMOS (1.43 ± 0.28 min and 1.52 ± 0.61 min, respectively). Image quality analysis revealed that PSP was superior in sharpness/definition and brightness/contrast, whereas no significant differences were observed compared to CMOS (p > 0.05). Moreover, no differences were noticed in technique accuracy regarding angulation errors and cone cutting (p > 0.05). However, placement errors with PSP had significantly higher average scores than CMOS (1.11 ± 0.77 and 0.67 ± 0.85, respectively; p < 0.01).

Conclusion: Dental students would benefit from being trained on both receptors to be able to adapt to a diversified workplace. Radiographic images obtained by dentistry students demonstrate that PSP and CMOS exhibit similar parameters regarding quality and accuracy, except in placement where PSP demonstrates greater accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jdd.13812DOI Listing

Publication Analysis

Top Keywords

photostimulable phosphor
8
phosphor plates
8
metal oxide
8
oxide semiconductor
8
radiographic images
8
psp cmos
8
generate radiograph
8
image quality
8
sharpness/definition brightness/contrast
8
angulation errors
8

Similar Publications

Comparison of radiographic imaging quality/accuracy using photostimulable phosphor plates and metal oxide semiconductor receptors.

J Dent Educ

December 2024

Instituto de Odontoestomatología, Escuela de Odontología, Facultad de Medicina, Universidad Austral de Chile, Valdivia, Chile.

Aim: To compare thequality and accuracy of radiographic images obtained by dentistry students from a Chilean university using photostimulable phosphor plates (PSP) and complementary metal oxide semiconductor (CMOS) receptors.

Materials And Methods: An experimental study was carried out in which 31 dental students used PSP and CMOS receptors to acquire radiographic images with the aid of a phantom. The time required to generate a radiograph was recorded.

View Article and Find Full Text PDF

In the working environment, machines without vibrations are non-existent. The abnormal operating conditions of machines can be discerned through characteristic patterns within vibration signals. Therefore, real-time, low-cost vibration sensing is essential for industrial applications to track the status of machines.

View Article and Find Full Text PDF

Objectives: To evaluate the antimicrobial efficacy of white vinegar, acetic acid, and peracetic acid on photostimulable phosphor (PSP) plates disinfection, and to assess the disinfectant influence on the radiographic quality.

Methods: Eight PSP plates (Express system) were contaminated with Streptococcus mutans and Candida albicans. These plates were wiped with tissues without any substance, with white vinegar, acetic acid, and peracetic acid, followed by an agar imprint.

View Article and Find Full Text PDF

Purpose: To evaluate the radiopacities of CAD-CAM materials using digital techniques.

Methods: Five different CAD-CAM materials were used (Cerasmart, LAVA Ultimate, Cerec Blocs C, Tetric CAD, and IPS e.max CAD) in this study (n= 5).

View Article and Find Full Text PDF

Background: Dental radiography is an integral part of intraoral evaluation. Children are often uncomfortable during the placement of film or sensor due to the impingement of the soft tissues. Thus, the perception of pain with three intraoral radiographic methods in children was evaluated using three subjective pain rating scales.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!