Geophysical techniques have become increasingly crucial for characterizing landfills, offering noninvasive methods for subsurface exploration and contamination assessment. In this study, an integrated geophysical approach-utilizing magnetic, electrical resistivity tomography (ERT), and transient electromagnetic (TEM) surveys-was employed to characterize the Weidenpesch landfill in Cologne, Germany and assess potential groundwater contamination. The results from these methods were consistent, effectively delineating the landfill boundaries and identifying possible contamination. The waste body was distinguished by its relatively low resistivity values with an average value of 1-10 Ω·m in the western and central parts of the landfill and 20-50 Ω·m at its eastern part in contrast with the surrounding high-resistivity gravelly sand layer (several hundreds of Ω·m), and a depth of up to 15 m. The variability in conductivity and magnetic susceptibility across different landfill sections indicated the heterogeneity of buried materials. Additionally, the ERT and TEM data indicate low resistivity values (below 5 Ω·m) at depths of 20-25 m. A correlation with the borehole data suggests that this may represent a contaminated coal/clay layer. Furthermore, repeated TEM measurements revealed significant variation in subsurface conductivity over time, highlighting the need for continuous monitoring. This study demonstrates the effectiveness of an integrated geophysical approach for providing a comprehensive understanding of subsurface landfill conditions, which is essential for informed environmental management and remediation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11666579PMC
http://dx.doi.org/10.1038/s41598-024-83848-9DOI Listing

Publication Analysis

Top Keywords

transient electromagnetic
8
resistivity tomography
8
integrated geophysical
8
low resistivity
8
resistivity values
8
landfill
6
joint interpretation
4
interpretation magnetic
4
magnetic transient
4
electromagnetic electric
4

Similar Publications

Airborne transient electromagnetic (ATEM) surveys provide a fast, flexible approach for identifying conductive metal deposits across a variety of intricate terrains. Nonetheless, the secondary electromagnetic response signals captured by ATEM systems frequently suffer from numerous noise interferences, which impede effective data processing and interpretation. Traditional denoising methods often fall short in addressing these complex noise backgrounds, leading to less-than-optimal signal extraction.

View Article and Find Full Text PDF

We demonstrate that at the rim of the photon sphere of a black hole, the quantum statistics transition takes place in any multi-particle system of indistinguishable particles, which passes through this rim to the inside. The related local departure from Pauli exclusion principle restriction causes a decay of the internal structure of collective fermionic systems, including the collapse of Fermi spheres in compressed matter. The Fermi sphere decay is associated with the emission of electromagnetic radiation, taking away the energy and entropy of the falling matter without unitarity violation.

View Article and Find Full Text PDF

There is compelling evidence that the absorption of low-energy UV radiation directly by DNA in solution generates guanine radicals with quantum yields that are strongly dependent on the secondary structure. Key players in this unexpected phenomenon are the photo-induced charge transfer () states, in which an electric charge has been transferred from one nucleobase to another. The present work examines the factors affecting the population of these states during electronic relaxation.

View Article and Find Full Text PDF

The application of a pulsed magnetic field (PMF) during a metallurgy solidification process has proven to be an effective method in refining the grain size and improving the mechanical performance of the material. However, fewer works were reported in the realm of laser additive manufacturing (LAM) and the mechanism of grain refinement consequent to the PMF is still unclear. In this work, numerical models were developed to study the thermal-fluid characteristics in the Ti-alloy melt pool generated during the laser scanning process under the effect of a combined direct current (DC) electric field and PMF.

View Article and Find Full Text PDF

Geophysical techniques have become increasingly crucial for characterizing landfills, offering noninvasive methods for subsurface exploration and contamination assessment. In this study, an integrated geophysical approach-utilizing magnetic, electrical resistivity tomography (ERT), and transient electromagnetic (TEM) surveys-was employed to characterize the Weidenpesch landfill in Cologne, Germany and assess potential groundwater contamination. The results from these methods were consistent, effectively delineating the landfill boundaries and identifying possible contamination.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?