Purpose: Pars Plana Vitrectomy (PPV) is a primary surgical method for rhegmatogenous retinal detachment (RRD). The introduction of the 3D head-up system has provided ophthalmologists with a new surgical experience. This study aims to compare the surgical outcomes between 3D low-light intensity-assisted and traditional eyepiece-assisted PPV for RRD. Trial Registration and Design: A prospective randomized controlled design was employed to compare the surgical outcomes of 3D low-light intensity-assisted and traditional eyepiece-assisted PPV for RRD. Forty eyes of 40 eligible patients were randomly assigned to either the 3D group or the eyepiece group. Surgical parameters, intraoperative conditions, and postoperative recovery were assessed over a six-month follow-up period. The research protocol underwent review and approval by the Medical Ethics Committee of Xuzhou First People's Hospital (xyy11 [2012] 026) and registered with the China Clinical Trial Registration Center (No. ChiCTR2200600522, Registration Date: 2022.06.04).

Methods: The optical intensity parameters of optical fibers and chandeliers were set according to the minimum lighting standard for 25G PPV. Surgery duration and intraoperative conditions were documented. Post-surgery, the light intensity of the optical fiber and chandeliers during surgery was measured using a photometer. Patients were followed up for six months to assess their postoperative recovery. Statistical analysis was performed using SPSS 26.0 software, with p < 0.05 indicating statistically significant differences.

Results: There was no statistically significant difference between the two groups in baseline data (p > 0.05). PPV was completed in all patients, and there was no statistically significant difference in surgery time between the two groups (p > 0.05). The optical fiber and chandelier light intensity in the 3D group were significantly lower than those in the eyepiece group, and the difference being statistically significant (p < 0.001). Six months after surgery, the retinal attachment rate was 100 %. Post-surgery, both best corrected visual acuity (BCVA) and intraocular pressure (IOP) were significantly higher than pre-surgery levels. There were no significant differences between the two groups in terms of retinal attachment rate, BCVA, IOP, and flash electroretinogram (p > 0.05).

Conclusions: Compared to the traditional eyepiece, the 3D head-up system can effectively complete surgery under lower illumination intensity. The anatomical restoration and functional success of the retina after surgery are equivalent.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000543135DOI Listing

Publication Analysis

Top Keywords

outcomes low-light
12
low-light intensity-assisted
12
intensity-assisted traditional
12
traditional eyepiece-assisted
12
pars plana
8
plana vitrectomy
8
rhegmatogenous retinal
8
retinal detachment
8
head-up system
8
compare surgical
8

Similar Publications

Purpose: Pars Plana Vitrectomy (PPV) is a primary surgical method for rhegmatogenous retinal detachment (RRD). The introduction of the 3D head-up system has provided ophthalmologists with a new surgical experience. This study aims to compare the surgical outcomes between 3D low-light intensity-assisted and traditional eyepiece-assisted PPV for RRD.

View Article and Find Full Text PDF

Objective: To explore the clinical efficacy of modified limbal stem cell transplantation(Modified LSC transplantation) and bandage contact lens(BCL) implantation in pterygium surgery.

Methods: A total of 479 patients with primary pterygium who were admitted to our hospital from March 2019 to March 2023 were randomly divided into three groups: the normal group (Group A: 89 patients), the control group (Group B: 195 patients), and the modified group (Group C: 195 patients). Each group received different intervention measures.

View Article and Find Full Text PDF

Usability of Light-Linking Technology for Infusion Line Identification: A Simulation Study With ICU Nurses.

J Infus Nurs

November 2024

Author Affiliations: Department of Implementation Science (Huffman and Munn), Center for Experiential and Applied Learning (Saunders), and Department of Biostatistics and Data Science (Russell), Wake Forest University School of Medicine (Gonzales), Winston-Salem, North Carolina; Center for Nursing Research (Huffman) and Comprehensive Cancer Center (Butcher), Atrium Health Wake Forest Baptist, Winston-Salem, North Carolina; Atrium Health Wake Forest Baptist Medical Center, Winston-Salem, North Carolina (Hampton).

Critical care nurses are faced with increasing task loads due to increasing patient complexity. In addition to this complexity, most critical care patients have a maze of infusion and monitoring lines that must be navigated when administering medications. Task load is escalated when a nurse must identify an injection port and administer a medication rapidly.

View Article and Find Full Text PDF

Studies have shown that vehicle trajectory data are effective for calibrating microsimulation models. Light Detection and Ranging (LiDAR) technology offers high-resolution 3D data, allowing for detailed mapping of the surrounding environment, including road geometry, roadside infrastructures, and moving objects such as vehicles, cyclists, and pedestrians. Unlike other traditional methods of trajectory data collection, LiDAR's high-speed data processing, fine angular resolution, high measurement accuracy, and high performance in adverse weather and low-light conditions make it well suited for applications requiring real-time response, such as autonomous vehicles.

View Article and Find Full Text PDF

To assess the agreement and repeatability of scotopic pupil size measurement using 2WIN-S (Adaptica, Padova, Italy) portable refractor in Chinese adults. This prospective non-randomized open-label controlled study assessed the scotopic pupil size of 100 right eyes using OPD-Scan III (Optical path difference) (Nidek Technologies, Gamagori, Japan) and 2WIN-S. OPD-Scan III and 2WIN-S measure pupil size using infrared light and detector, while 2WIN-S measures bilateral eyes simultaneously, OPD-Scan III measures unilateral eyes individually.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!