AI Article Synopsis

  • A model was developed to analyze the noise and randomness in fluorescence signals under continuous wave (CW) and time-gated (TG) conditions, focusing on how different excitation photon flux affects fluorophore emission.
  • Both ensemble and stochastic models were validated through Monte Carlo molecular dynamics simulations using the Gillespie algorithm, showing their effectiveness in capturing the dynamics of fluorescence.
  • The study explores the implications of the model for designing biomolecular fluorescence detection systems, emphasizing trade-offs related to signal-to-noise ratios and detection limits as systems shrink to micro- and nano-scales, highlighting the advantages of TG systems in terms of cost and complexity when suitable fluorophores are used.

Article Abstract

We present a model for the noise and inherent stochasticity of fluorescence signals in both continuous wave (CW) and time-gated (TG) conditions. When the fluorophores are subjected to an arbitrary excitation photon flux, we apply the model and compute the evolution of the probability mass function (pmf) for each quantum state comprising a fluorophore's electronic structure, and hence the dynamics of the resulting emission photon flux. Both the ensemble and stochastic models presented in this work have been verified using Monte Carlo molecular dynamic simulations that utilize the Gillespie algorithm. The implications of the model on the design of biomolecular fluorescence detection systems are explored in three relevant numerical examples. For a given system, the quantum-limited signal-to-noise ratio (QSNR) and limits of detection are computed to demonstrate how key design tradeoffs are quantified. We find that as systems scale down to micro- and nano- dimensions, the interplay between the fluorophore's photophysical qualities and use of CW or TG has ramifications on optimal design strategies when considering optical component selection, measurement speed, and system energy requirements. While CW systems remain a gold standard, TG systems can be leveraged to overcome cost and system complexity hurdles when paired with the appropriate fluorophore.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11666023PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0313949PLOS

Publication Analysis

Top Keywords

inherent stochasticity
8
limits detection
8
photon flux
8
systems
5
stochasticity noise
4
noise limits
4
detection continuous
4
continuous time-gated
4
time-gated fluorescence
4
fluorescence systems
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!