Background: Patients with symptomatic aortic stenosis are a vulnerable population with associated cardiac damage and a significant comorbidity burden. In this study we aimed to determine the rate, factors associated with, and prognostic value of poor functional status (New York Heart Association [NYHA] class III-IV) in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (TAVR).
Methods: This multicenter study included 6363 transarterial TAVR patients, classified according to baseline functional status (NYHA class I or II vs III or IV).
Results: A total of 3800 (60%) patients presented with NYHA class III or IV before the TAVR procedure. Atrial fibrillation (odds ratio [OR], 1.32; 95% confidence interval [CI], 1.11-1.58; P = 0.002), chronic kidney disease (CKD; OR, 1.73; 95% CI, 1.45-2.05; P < 0.001), chronic obstructive pulmonary disease (COPD; OR, 1.65; 95% CI, 1.32-2.05; P < 0.001), reduced left ventricular ejection fraction (OR, 2.28; 95% CI, 1.70-3.05; P < 0.001), and moderate and severe pulmonary hypertension were associated with a poor functional status. At 1-year follow-up, patients with NYHA class III or IV had higher rates of mortality (8.81 per 100 person-years [95% CI, 7.57-10.15] vs 13.12 per 100 person-years [95% CI, 11.80-14.58]; log rank, P < 0.001) and heart failure hospitalization (8.25 per 100 person-years [95% CI, 7.05-9.65] vs 12.5 per 100 person-years [95% CI, 11.24-14.00]; log rank, P = 0.005). Comorbidity factors (COPD, CKD) and signs of cardiac damage (atrial fibrillation, pulmonary hypertension) determined an increased risk of poorer clinical outcomes (P < 0.01 for all).
Conclusions: More than half of the patients undergoing TAVR in the contemporary era have presented with advanced functional class before the procedure, and this was associated with a greater comorbidity and cardiac damage burden. Patients with poorer baseline functional status exhibited worse clinical outcomes at 1-year follow-up. These findings highlight the need for further study on earlier interventions for patients with aortic stenosis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.cjca.2024.12.025 | DOI Listing |
Eur Heart J Case Rep
January 2025
Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka 589-8511, Japan.
Background: The initial outcomes of transcatheter aortic valve replacement in patients with left ventricular outflow tract calcification are poor. Furthermore, balloon-expandable transcatheter aortic valve replacement is associated with an increased risk of annular rupture, and self-expandable transcatheter aortic valve replacement is associated with worse post-operative residual paravalvular leakage grades. Therefore, developing an optimal method for transcatheter aortic valve replacement for patients with left ventricular outflow tract calcification is desirable.
View Article and Find Full Text PDFEur Heart J Cardiovasc Imaging
January 2025
Heart Institute. Department of Cardiology. Cardiovascular Imaging Unit. Hospital Universitari Germans Trias i Pujol, Barcelona, Spain.
Aims: How the underlying etiology and pathophysiology of left ventricular (LV) hypertrophy affects LA remodeling and function remains unexplored. The present study aims to investigate the influence of various hypertrophic phenotypes on LA remodeling and function.
Methods And Results: Patients with LV hypertrophy who underwent cardiac magnetic resonance (CMR) were compared to a control group.
Eur Heart J Cardiovasc Imaging
January 2025
Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy.
Aims: This study evaluates whether multi-chamber myocardial deformation analysis using speckle tracking echocardiography (STE) can enhance validated current staging systems and improve risk stratification for patients with moderate-to-severe aortic stenosis (AS).
Methods And Results: We reanalyzed 2D, Doppler, and STE data obtained from two cohorts: derivation (654 patients, median age: 82 years; 51% men) and validation (237 patients, median age: 77 years; 55% men) with at least moderate AS (aortic valve area<1.5 cm2).
Eur J Cardiothorac Surg
January 2025
Department of Cardiac Surgery, University Hospital Quironsalud Madrid, Spain.
Objectives: The Ross procedure for aortic regurgitation (AR) and abnormal aortic valve morphologies is associated with an increased risk of autograft dilatation. Autograft support may ameliorate this problem. We analyzed the results for all haemodynamic lesions and the effect of autograft support.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.
Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.
Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!