Dual-mode exosome detection leveraging a nanozyme-active artificial receptor: PDA@Fe@Zn-based nucleic acid aptamer sensor.

Talanta

Shanghai Key Laboratory of Functional Materials Chemistry, School of Chemistry & Molecular Engineering, East China University of Science and Technology, Shanghai, 200237, PR China. Electronic address:

Published: December 2024

Exosomes, extracellular vesicles crucial for intercellular communication, are emerging as significant biomarkers for disease diagnosis, especially in cancer. This study presented a dual-mode exosome detection platform using polydopamine microspheres doped with iron and zinc ions (PDA@Fe@Zn). These materials served as both artificial receptors for nucleic acid aptamers and nanozymes with peroxidase-like activity. By integrating colorimetric and fluorescence detection, the platform enables cross-validation of results. PDA@Fe@Zn nanozymes catalyzed the TMB-HO reaction under acidic conditions, producing a colorimetric signal proportional to exosome concentration. Concurrently, the fluorescence of FAM-labeled aptamers was dynamically quenched by PDA@Fe@Zn and the presence of exosomes restores the fluorescence signal for a "turn-on" detection mode. DNase I amplified detection signals by cleaving bound exosomes for multiple cycles, achieving a limit of detection (LOD) of 4.7 × 10 particles/mL for colorimetric detection and 2.2 × 10 particles/mL for fluorescence detection. Notably, the colorimetric platform revealed that the relative expression of the CD63 protein on exosomes from breast cancer cells MCF-7 and MDA-MB-231 was approximately 2.7 and 2.4 times higher, respectively, than in normal breast cells MCF-10A; similar fold changes of 2.9 and 2.4 were observed with fluorescence detection, underscoring the robustness of the dual-mode system. The platform demonstrated rapid detection (within 30 min), high sensitivity, strong anti-interference capability, and the ability to distinguish exosomes from cancerous and normal cells effectively.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2024.127380DOI Listing

Publication Analysis

Top Keywords

fluorescence detection
12
detection
10
dual-mode exosome
8
exosome detection
8
nucleic acid
8
detection platform
8
exosomes
5
fluorescence
5
detection leveraging
4
leveraging nanozyme-active
4

Similar Publications

In this study, nitrogen-doped carbon nanodots (N-CDs) with temperature and fluorescence sensing were prepared via hydrothermal method using L-lysine and ethylenediamine as precursors. The synthesized N-CDs exhibited spherical morphology with sizes ranging from 2.8 to 5.

View Article and Find Full Text PDF

This study addresses the critical issue of irreversible oxidation in hypochlorite (ClO⁻) sensing by a phenothiazine-based compound, which typically leads to the probe's degradation and loss of functionality. We introduce a novel fluorescence probe, (2-(5-(10 H-phenothiazin-10-yl)thiophen-2-yl)-1 H-benzo[d]imidazol-6-yl)(phenyl)methanone (PTH-BP), specifically designed to enhance ClO⁻ detection efficiency. PTH-BP exhibits strong aggregation-induced emission (AIE), emitting deep orange fluorescence at 620 nm with a large Stokes shift of 195 nm, and achieves an impressive detection limit of 1 nM in ACN/PBS buffer solutions.

View Article and Find Full Text PDF

Harmonized technical standard test methods for quality evaluation of medical fluorescence endoscopic imaging systems.

Vis Comput Ind Biomed Art

January 2025

School of Engineering Medicine and School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China.

Fluorescence endoscopy technology utilizes a light source of a specific wavelength to excite the fluorescence signals of biological tissues. This capability is extremely valuable for the early detection and precise diagnosis of pathological changes. Identifying a suitable experimental approach and metric for objectively and quantitatively assessing the imaging quality of fluorescence endoscopy is imperative to enhance the image evaluation criteria of fluorescence imaging technology.

View Article and Find Full Text PDF

The development of probes for the efficient detection of volatile organic compounds is crucial for both human health protection and environmental monitoring. In this study, we successfully synthesized a ratiometric fluorescent sensing material [Eu-UiO-67 (1:1)], featuring dual-emission fluorescence peaks via a one-pot method. This material demonstrated exceptional ratiometric fluorescence recognition properties for liquid styrene and isoprene, achieving low limit of detections (LODs) of 6.

View Article and Find Full Text PDF

Innovative double-emission carbon dots (DE-CDs) were synthesized via a one-step hydrothermal method using fennel and m-phenylenediamine (m-PD) as precursors. These DE-CDs exhibited dual emission wavelengths at 432 and 515 nm under different excitations, making them highly versatile for fluorescence-based applications. The fluorescence of the DE-CDs was efficiently quenched by tetracycline (TC) through the inner filter effect (IFE), allowing for the construction of a sensitive dual-response fluorescent sensor.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!