A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High-Power Short-Duration Radiofrequency Application for Faster and Safer Pulmonary Vein Isolation: The POWER-FAST III Trial. | LitMetric

Background: The optimal radiofrequency application (RFa) parameters for safe and durable pulmonary vein isolation (PVI) are debated. High-power short-duration (HPSD) has been used as an alternative to conventional power delivery (CPD).

Objectives: This study sought to compare HPSD 70 W/9-10 s (HPSD-70) with CPD 25-40 W in patients undergoing PVI.

Methods: Patients were randomized to HPSD-70 or CPD (25-40). The primary outcomes were freedom from atrial arrhythmia recurrences and the incidence of esophageal thermal lesions (EDELs) after ablation.

Results: Among 304 patients randomized, 301 remained in the study (median age: 61 years; Q1-Q3: 53-69 years; 72% men): 294 patients (97.7%) underwent ablation, 285 (94.7%) underwent endoscopy, and 290 (98.6%) completed the follow-up. At 12 months, 100 patients (73.5%) in the CPD (25-40) group and 87 patients (67%) in the HPSD-70 group were free from recurrences off antiarrhythmic drugs (HR: 1.28; 95% CI: 0.82-1.99; P = 0.28). The incidences of EDELs were 2.7% in the CPD (25-40) group and 3.6% in the HPSD-70 group (P = 0.94). Median left atrial dwell (153 vs 137 min; P = 0.03) and total RF times for definitive PVI (31 vs 11.2 min; P < 0.001) were shorter with HPSD-70 ablation. Four symptomatic embolic events (2 strokes, 1 transient ischemic attack, and 1 splenic infarct) occurred with HPSD-70 and none with CPD (25-40) RFa (P = 0.056).

Conclusions: HPSD-70 RFa was noninferior to prevent arrhythmia recurrences, and the incidence of EDELs was similar compared with CPD (25-40) RFa. The embolic events were numerically higher in the HPSD-70 group. (High Radiofrequency Power for Faster and Safer Pulmonary Vein Ablation Trial [POWER FAST III]; NCT04153747).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacep.2024.10.009DOI Listing

Publication Analysis

Top Keywords

cpd 25-40
20
pulmonary vein
12
hpsd-70 cpd
12
hpsd-70 group
12
high-power short-duration
8
radiofrequency application
8
faster safer
8
safer pulmonary
8
vein isolation
8
hpsd-70
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!