Generating synthetic CT images from unpaired head and neck CBCT images and validating the importance of detailed nasal cavity acquisition through simulations.

Comput Biol Med

Division of Obstructive Sleep Apnea Syndrome Diagnosis, School of Mechanical Engineering, College of Engineering, Yonsei University, Seoul, Republic of Korea; The Center for Hemodynamic Precision Medical Platform, Seoul, Republic of Korea. Electronic address:

Published: December 2024

Background And Objective: Computed tomography (CT) of the head and neck is crucial for diagnosing internal structures. The demand for substituting traditional CT with cone beam CT (CBCT) exists because of its cost-effectiveness and reduced radiation exposure. However, CBCT cannot accurately depict airway shapes owing to image noise. This study proposes a strategy utilizing a cycle-consistent generative adversarial network (cycleGAN) for denoising CBCT images with various loss functions and augmentation strategies, resulting in the generation of denoised synthetic CT (sCT) images. Furthermore, through a rule-based approach, we were able to automatically segment the upper airway in sCT images with high accuracy. Additionally, we conducted an analysis of the impact of finely segmented nasal cavities on airflow using computational fluid dynamics (CFD).

Methods: We trained the cycleGAN model using various loss functions and compared the quality of the sCT images generated by each model. We improved the artifact removal performance by incorporating CT images with added Gaussian noise augmentation into the training dataset. We developed a rule-based automatic segmentation methodology using threshold and watershed algorithms to compare the accuracy of airway segmentation for noise-reduced sCT and original CBCT. Furthermore, we validated the significance of the nasal cavity by conducting CFD based on automatically segmented shapes obtained from sCT.

Result: The generated sCT images exhibited improved quality, with the mean absolute error decreasing from 161.60 to 100.54, peak signal-to-noise ratio increasing from 22.33 to 28.65, and structural similarity index map increasing from 0.617 to 0.865. Furthermore, by comparing the airway segmentation performances of CBCT and sCT using our proposed automatic rule-based algorithm, the Dice score improved from 0.849 to 0.960. Airway segmentation performance is closely associated with the accuracy of fluid dynamics simulations. Detailed airway segmentation is crucial for altering flow dynamics and contributes significantly to diagnostics.

Conclusion: Our deep learning methodology enhances the image quality of CBCT to provide anatomical information to medical professionals and enables precise and accurate biomechanical analysis. This allows clinicians to obtain precise quantitative metrics and facilitates accurate assessment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.compbiomed.2024.109568DOI Listing

Publication Analysis

Top Keywords

sct images
16
airway segmentation
16
images
8
head neck
8
cbct images
8
nasal cavity
8
loss functions
8
fluid dynamics
8
cbct
7
airway
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!