The inhalation-exhalation (I:E) ratio, known to be an indicator of respiratory disease, is the ratio between the inhalation phase and exhalation phase of each breath. Here, we report on results from a non-contact monitoring method for the determination of the I:E ratio. This employs a depth sensing camera system that requires no sensors to be physically attached to the patient. A range of I:E ratios from 0.3 to 1.0 over a range of respiratory rates from 4 to 40 breaths/min were generated by healthy volunteers, producing a total of 3,882 separate breaths for analysis. Depth information was acquired using an Intel D415 RealSense camera placed at 1.1 m from the subjects' torso. This data was processed in real-time to extract depth changes within the subjects' torso region corresponding to respiratory activity. This was further converted into a respiratory signal from which the I:E ratio was determined (I:E[Formula: see text]). I:Edepth was compared to spirometer data (I:E[Formula: see text]). A Bland Altman analysis produced a mean bias of -0.004, with limits of agreement [-0.234, 0.227]. A linear regression analysis produced a line of best fit given by I:E[Formula: see text] I:Espiro - 0.006, with 95% confidence intervals for the slope [0.988, 1.019] and intercept [-0.017, 0.004]. We have demonstrated the viability of a non-contact monitoring method for determining the I:E ratio on healthy subjects breathing without mechanical support. This measure may be useful in monitoring the deterioration in respiratory status and/or response to therapy within the patient population. Clinical and Translational Impact Statement - The I:E ratio is an indicator of disease severity in COPD and asthma. Non-contact continuous monitoring of I:E ratio will offer the clinician a powerful new tool for respiratory monitoring.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11655103 | PMC |
http://dx.doi.org/10.1109/JTEHM.2024.3496196 | DOI Listing |
Materials (Basel)
December 2024
Department of Mechanics of Materials and Constructions, Faculty of Engineering, Vrije Universiteit Brussel, B-1050 Brussels, Belgium.
Cementitious materials are susceptible to damage not only from mechanical loading, but also from environmental (physical, chemical, and biological) factors. For Textile-Reinforced Cementitious (TRC) composites, durability poses a significant challenge, and a reliable method to assess long-term performance is still lacking. Among various durability attacks, freeze-thaw can induce internal cracking within the cementitious matrix, and weaken the textile-matrix bond.
View Article and Find Full Text PDFCrit Care
January 2025
Graduate School of System Design, Tokyo Metropolitan University, Tokyo, Japan.
Mater Horiz
January 2025
School of Materials Science and Engineering, Energy Materials and Devices Key Lab of Anhui Province for Photoelectric Conversion, Anhui University, Hefei, Anhui 230601, China.
The triboelectric nanogenerator (TENG) has been proved to be a very promising marine energy harvesting technology. Herein, we have developed a high-performance triboelectric nanogenerator (SD-TENG) with low friction, high durability, swing-induced counter-rotating motion mechanism (SICRMM) and dual potential energy storage and release strategy (DPESRS). The unique counter-rotating motion mechanism enabled SD-TENG to convert the external linear and swing motion energy into rotation motion energy of the inner and outer cylinders, and then converted it into a controllable power output.
View Article and Find Full Text PDFF S Sci
December 2024
The Ronald O. Perelman and Claudia Cohen Center for Reproductive Medicine, Weill Cornell Medicine, New York, NY, 10021, USA. Electronic address:
Anal Bioanal Chem
December 2024
School of Medical Technology, Beijing Institute of Technology, Beijing, 100081, PR China.
Point-of-care testing methods are essential for the large-scale diagnosis and monitoring of bacterial infections. This study introduces an integrated platform designed for the simultaneous detection of pathogenic bacteria. Users can simply inject samples into the system, which then conducts the entire procedure in a fully automated manner, eliminating the need for external power sources, all within 60 min or less.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!