Aim: To establish an animal model of form deprivation amblyopia based on a simulated cataract intraocular lens (IOLs).
Methods: Poly(dimethyl siloxane)-SiO thin films (PSF) with different degrees of opacity as IOL materials were prepared. The light transmission of the PSF-IOL was measured, and its biosafety was determined by cell counting kit (CCK)-8 assay using the HLEC-B3 cell line and ARPE-19 cell line. Subsequently, the safety was determined by implanting the PSF-IOL with 10% wt SiO into the right eyes of New Zealand white rabbits (PSF-IOL group), and compared with two control groups: contralateral comparison group and normal control (NC) group (Contralateral comparison group: the fellow eye; NC group: a group of binocular normal rabbits without intervention). The flash visual-evoked potentials (F-VEPs) were measured to verify amblyopia.
Results: PSFs containing 0, 2%, and 10% wt SiO were successfully constructed. The 0 SiO PSF was transparent, while the 10% wt SiO PSF was completely opaque. It was found that PSF did not induce unwanted cytotoxicity in HLECs and ARPE19 cells . , PSF-IOL with 10% wt SiO was also non-toxic, and no significant inflammation or structural changes occurred after four weeks of PSF-IOL implantation. Finally, our IOL-simulated congenital cataract rabbit detected by F-VEPs suggested tentative amblyopia.
Conclusion: A PSF-IOL that mimics cataracts is created. A novel form deprivation model is created by the IOL-simulated congenital cataract rabbit. It can be developed fast and stable and holds great potential for future study.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11589453 | PMC |
http://dx.doi.org/10.18240/ijo.2024.12.04 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!