Enhancing Amperometric Ozone Gas Sensing with Room-Temperature Ionic Liquids and Platinum-Based Electrodes.

ACS Appl Mater Interfaces

Key Laboratory for Advanced Materials and Joint International Research Laboratory of Precision Chemistry and Molecular Engineering, Feringa Nobel Prize Scientist Joint Research Centre, School of Chemistry and Molecular Engineering, East China University of Science & Technology, Shanghai 200237, China.

Published: January 2025

Ozone (O) poses serious health risks, prompting numerous countries to implement regulations that establish exposure limits and emission controls, for example, the air quality index (AQI) for O ranging from 50 to 150 parts per billion (ppb), with natural levels at around 30 ppb. Electrochemical sensors are favored for detecting pollutant gases due to their high sensitivity, low cost, portability, energy efficiency, and capability for selective detection. In this study, we developed an O sensor employing carbon-supported Pt-based binary and ternary nanorods (NRs) combined with room-temperature ionic liquids (RTILs) as electrolytes, aiming at highly sensitive and selective detection of O at ppb levels. Initial screening of the O sensing performance across different electrolytes identified HSO and [Cmpyrr][NTf] (BMP) as the most sensitive options. BMP outperformed HSO in terms of linearity, selectivity, reproducibility, and response/recovery times, despite a relatively lower sensitivity. Electrochemical testing of Pt, PtAu, PtAg, and PtAuAg NR electrodes in BMP revealed that the addition of Au enhanced the linear response, while Ag improved sensitivity. Consequently, the ternary PtAuAg NR electrode exhibited the highest sensitivity (10.5 nA/ppm (parts per million)) and a broad detection range, fulfilling the AQI requirements for O. The current response from the PtAuAg NR electrode closely aligned with results from an ultraviolet (UV) photometric analyzer, confirming its accuracy. Notably, this electrode contains only 20 wt % noble metals, which reduces the overall cost to just 11% of that of a traditional pure Au electrode.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.4c18003DOI Listing

Publication Analysis

Top Keywords

room-temperature ionic
8
ionic liquids
8
selective detection
8
ptauag electrode
8
enhancing amperometric
4
amperometric ozone
4
ozone gas
4
gas sensing
4
sensing room-temperature
4
liquids platinum-based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!