Basing on the utilization of the benefit-injury concept the authors put forward an approach to the substantiation of permissible errors in the values of the mean doses intended for the patient's critical organs in x-ray examination. It was shown that in the elaboration of methods to determine the mean tissue doses one should aim at reaching a mean quadratic error of +/- 30% in their values.

Download full-text PDF

Source

Publication Analysis

Top Keywords

[basis allowable
4
allowable errors
4
errors determining
4
determining doses
4
doses patients
4
patients roentgenologic
4
roentgenologic examinations]
4
examinations] basing
4
basing utilization
4
utilization benefit-injury
4

Similar Publications

Introduction And Objective: Water in installations in hospitals and social welfare homes (SWHs) should meet the requirements of the Directive of the European Parliament and of the Council on the quality of water intended for human consumption and national regulations issued on its basis. At present, 60 species of bacteria of the genus Legionella sp. are known (of which 30 are considered as pathogenic for humans), and more than 80 serologic groups.

View Article and Find Full Text PDF

The snaplage residue presents itself as a potential alternative roughage source in finishing systems, owing to its high fiber concentration which aids in maintaining rumen health. Nevertheless, the performance of animals will hinge on both the allowance and the nutritive value it offers. This study aimed to evaluate different stocking rates of heifers grazing snaplage residue as an exclusive source of fiber on finishing phase performance.

View Article and Find Full Text PDF

Temporal mechanisms underlying visual processing bias in peri-hand space.

Atten Percept Psychophys

November 2024

Department of Humanities and Social Sciences, Indian Institute of Technology RoorkeeRoom No. 513, Uttarakhand - 247 667, Roorkee, India.

The immediate space surrounding the hands has often been termed the peri-hand space (PHS), and is characterized by a smaller reaction time (RT), better detection, and enhanced accuracy for stimuli presented in this space, relative to those stimuli presented beyond this space. Such behavioral changes have been explained in terms of a biased allocation of cognitive resources such as perception, attention, and memory, for the efficient processing of information presented in the PHS. However, in two experiments, the current study shows that these cognitive biases seem to have an underlying temporal basis.

View Article and Find Full Text PDF

The fatigue allowance effectively mitigates declines in physiological state due to work fatigue. An appropriate allowance rate facilitates timely recovery for employees and serves as a crucial basis for labor quota formulation. In this paper, the action mode in mechanical processing was extracted and disassembled into six action units.

View Article and Find Full Text PDF

The impact of tube voltage on the erosion of rotating x-ray anodes.

Med Phys

November 2024

Particle Physics, Astrophysics and Medical Imaging Department, KTH Royal Institute of Technology, Stockholm, Sweden.

Background: The permitted input power density of rotating anode x-ray sources is limited by the performance of available target materials. The commonly used simplified formulas for the focal spot surface temperature ignore the tube voltage despite its variation in clinical practice. Improved modeling of electron transport and target erosion, as proposed in this work, improves the prediction of x-ray output degradation by target erosion, the absolute x-ray dose output and the quality of diagnostic imaging and orthovolt cancer therapy for a wide range of technique factors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!