Simulated effects of surgical corrections on bone-implant micromotion and implant stresses in paediatric proximal femoral osteotomy.

Comput Biol Med

Griffith Center of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Australia; School of Medicine and Dentistry, Griffith University, Australia; Department of Orthopaedics, Children's Health Queensland Hospital and Health Service, Australia. Electronic address:

Published: December 2024

Background And Objective: Proximal femoral osteotomy (PFO) is a surgical intervention, typically performed on paediatric population, that aims to correct femoral deformities caused by different pathologies (e.g., slipped capital femoral epiphysis). A PFO involves introduction of an implant to fix the proximal and distal sections of femur following the surgical corrections. The femoral neck-shaft angle (NSA) and anteversion angle (AVA) are key geometric parameters that influence PFO outcomes. To date, the effects of NSA and AVA on bone-implant system mechanics in paediatric populations have not been examined.

Methods: This study used an established neuromusculoskeletal modelling process paired with finite element analysis to determine the sensitivity of the implanted femur's mechanics to variations in NSA and AVA during the stance phase of walking. Three male patients aged 9-12 years with different pathology (Spastic diplegia, Perthes disease and Slipped Capital Femoral Epiphysis), weight (377, 747, 842 N), height (1.39, 1.55, 1.71 m) and femur lengths (34.1, 39.4, 43.7 cm) and geometries (NSA: 143, 102, 111 deg; AVA: 29, 17, -22 deg) were examined. For each patient, a three-dimensional bone model was created from computed tomography imaging and digital surgical corrections were applied to systematically vary the NSA and AVA. Personalized motion and loading conditions driven from a neuromusculoskeletal modelling process were applied to each model and its associated permutations of NSA and AVA.

Results: Results indicated significant intra-participant variability in post-PFO bone-implant micromotion and peak von Mises stress on implant. For models with a post-surgery NSA of 135° and AVA of 12°, the averaged micromotion increased by 87 % and the peak von Mises stress decreased by 63% between patient 1 and 2. Between patient 2 and 3, the averaged micromotion decreased by 55% while the peak von Mises stress increased by 84%.

Conclusions: Furthermore, post-PFO bone-implant mechanics were sensitive to variation in NSA and AVA in a subject-specific manner. Optimization of PFO planning is recommended based on patient-specific characteristics.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.compbiomed.2024.109544DOI Listing

Publication Analysis

Top Keywords

nsa ava
16
surgical corrections
12
peak von
12
von mises
12
mises stress
12
bone-implant micromotion
8
proximal femoral
8
femoral osteotomy
8
slipped capital
8
capital femoral
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!