Exhaled breath volatile organic compounds (VOCs) are often collected and stored in sorbent tubes before thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) analysis. Information about the stability of VOCs during storage is needed to account for potential artifacts and monitor for losses. Additionally, information about the stability of VOC standards in solution is required to assess their performance as quality control and internal standards. We evaluated the stability of a standard mixture of 42 VOCs in dual-sorbent tubes containing Tenax® TA and Carbotrap 1TD over 60 d at commonly used storage conditions: room temperature (∼21 °C), 4 °C, and -80 °C. The same 42 VOCs were also evaluated for their stability in methanol over 60 d while stored at -20 °C. All samples were analyzed using TD-GC-MS. During storage, most VOCs were stable on sorbent after 60 d: 36/42 (86%), 39/42 (93%), and 41/42 (98%) had not statistically changed for room temperature, 4 °C and -80 °C, respectively, based on Spearman rank correlation coefficients and linear regression analysis. The isotopically labeled VOCs tested here are well-suited to serve as internal standards for pre-analysis or storage. Degradation of VOCs in solution was apparent after 60 d: 27/42 (64%) of VOCs had statistically decreased. The total VOC mixture had dropped to 90% of its original intensity after ∼22 d and a subset of VOCs typically used as internal standards dropped to 90% in ∼16 d. Analysts using similar mixtures should make a fresh solution at least every two weeks to ensure analytical accuracy. This study provides important insights into storage practices for both sorbent tubes and standard solutions, guiding analysts toward improved reliability and accuracy in exhaled breath analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1752-7163/ada05cDOI Listing

Publication Analysis

Top Keywords

internal standards
12
vocs
9
volatile organic
8
organic compounds
8
exhaled breath
8
sorbent tubes
8
evaluated stability
8
room temperature
8
°c -80
8
-80 °c
8

Similar Publications

Background And Aim: Managing obesity requires a comprehensive approach that involves therapeutic lifestyle changes, medications, or metabolic surgery. Many patients seek health information from online sources and artificial intelligence models like ChatGPT, Google Gemini, and Microsoft Copilot before consulting health professionals. This study aims to evaluate the appropriateness of the responses of Google Gemini and Microsoft Copilot to questions on pharmacologic and surgical management of obesity and assess for bias in their responses to either the ADA or AACE guidelines.

View Article and Find Full Text PDF

Cognitive resilience (CR) describes the phenomenon of individuals evading cognitive decline despite prominent Alzheimer's disease neuropathology. Operationalization and measurement of this latent construct is non-trivial as it cannot be directly observed. The residual approach has been widely applied to estimate CR, where the degree of resilience is estimated through a linear model's residuals.

View Article and Find Full Text PDF

Effects of obstructive sleep apnea on nocturnal changes in blood pressure - a retrospective study.

Hypertens Res

January 2025

School of Medicine, College of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan; #155 Section 2, Linong Street, Taipei, 112, Taiwan.

To explore the effects of obstructive sleep apnea (OSA) on nocturnal changes in blood pressure (BP), we enrolled 2037 participants who underwent polysomnography (PSG) between 2019 and 2020 and examined BP changes before and after sleep. BP was measured in the evening and the following morning using an electronic wrist sphygmomanometer in the supine position. The severity of OSA was determined by PSG and graded based on the apnea/hypopnea index (AHI).

View Article and Find Full Text PDF

Background: This study aimed to investigate the clinical characteristics and esophageal motility of patients with gastric cardia submucosal tumors (SMTs) and the associated changes after endoscopic resection based on high-resolution impedance manometry (HRIM).

Methods: From our electronic database, we identified patients who underwent pre-operative evaluation of gastric cardia SMTs between 2015 and 2023. All patients completed standardized symptom questionnaires and underwent endoscopic ultrasonography and HRIM.

View Article and Find Full Text PDF

Background: Surgery remains the cornerstone of treatment for rhabdomyosarcoma (RMS) in children. However, there is considerable variation in surgical management practices worldwide, highlighting the need for standardized Clinical Practice Guidelines (CPG).

Methods: The CPG development involved assembling a multidisciplinary group, prioritizing 10 key topic areas, conducting evidence searches, and synthesizing findings.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!