A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Unique Characteristics of Pulse-Echo Sensing Systems for Ultrasonic Immersion Testing in Harsh Environments. | LitMetric

Unique Characteristics of Pulse-Echo Sensing Systems for Ultrasonic Immersion Testing in Harsh Environments.

Sensors (Basel)

Department of Engineering Science and Mechanics, Penn State, University Park, PA 16802, USA.

Published: December 2024

Ultrasound is an excellent way to acquire data that reveal useful information about systems operating in harsh environments, which may include elevated temperature, ionizing radiation, and aggressive chemicals. The effects of harsh environments on piezoelectric materials have been studied in much more depth than the other aspects of ultrasonic transducers used in pulse-echo mode. Therefore, finite element simulations and laboratory experiments are used to demonstrate the unique characteristics of pulse-echo immersion testing. Using an aluminum nitride piezoelectric element mounted on a vessel wall, characteristics associated with electrode thickness, couplant, backing material, and an acoustic matching layer are investigated. Considering a wave path through a vessel wall and into a fluid containing a target, when the travel distance in the fluid is relatively short, it can be difficult to discern the target echo from the reverberations in the vessel wall. When an acoustic matching layer between the vessel wall and the fluid does not suffice, a simple subtractive signal-processing method can minimize the reverberations, leaving just the target echoes of interest. Simulations and experiments demonstrate that sufficient target echoes are detected to determine the time of flight. Furthermore, a simple disc-like surface anomaly on the target is detectable.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11645087PMC
http://dx.doi.org/10.3390/s24237748DOI Listing

Publication Analysis

Top Keywords

vessel wall
16
harsh environments
12
unique characteristics
8
characteristics pulse-echo
8
immersion testing
8
experiments demonstrate
8
acoustic matching
8
matching layer
8
wall fluid
8
target echoes
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!