A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Geostress-Adaptive Charge Structure Design and Field Validation for Machinery Room Excavation. | LitMetric

Geostress-Adaptive Charge Structure Design and Field Validation for Machinery Room Excavation.

Sensors (Basel)

School of Infrastructure Engineering, Nanchang University, Nanchang 330031, China.

Published: December 2024

The application of blasting in modern engineering construction is prized for its speed, efficiency, and cost-effectiveness. However, the resultant vibrations can have significant adverse effects on surrounding buildings and residents. The challenge of optimizing blasting procedures to satisfy excavation needs while minimizing vibration impacts is a critical concern in blasting excavation. This research addresses this challenge through the development of a 3D simulation and analysis model for an underground pumped storage power plant in East China, utilizing the LS-DYNA finite element analysis software. To explore the influence of charging structures on rock fragmentation and vibration propagation, three distinct blasting programs were formulated, each featuring varied configurations within the machinery room. The analysis revealed that the adoption of an optimized charging structure can significantly decrease damage to the protective layer by approximately 40%, while also reducing the impact on the upstream and downstream side walls by 27.25% and 12.03%, respectively, without compromising the efficacy of the main blast zone. Moreover, the vibration velocities at the remote measurement point were found to be reduced across multiple directions, indicating effective control of the vibration effects. The post-implementation of the optimized blasting strategy at the site, the assessment of the retained surrounding rock integrity, and the impact on protected structures demonstrated that the proposed solution met satisfactory outcomes. This study underscores the potential of simulation-based optimization in managing vibration risks during blasting operations, offering a valuable tool for engineers and practitioners in the field of underground construction.

Download full-text PDF

Source
http://dx.doi.org/10.3390/s24237738DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11645067PMC

Publication Analysis

Top Keywords

machinery room
8
blasting
6
vibration
5
geostress-adaptive charge
4
charge structure
4
structure design
4
design field
4
field validation
4
validation machinery
4
room excavation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!