Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Interest in adhesively bonded joints has significantly increased due to their numerous advantages over other joining techniques. However, they are frequently used in structures subjected to fatigue loading, which might cause defects such as cracks within the bondline. Thus, timely detection, localization, and size estimation of such defects are crucial for ensuring structural safety. This study focused on experimentally investigating crack length estimation in adhesively bonded joints under mode II fatigue loading. To analyze the crack growth, a comprehensive comparison was conducted between various techniques, such as visual testing, digital image correlation, optical backscatter reflectometry, and the analytical compliance-based beam method. In interrupted fatigue tests (static acquisition), digital image correlation and optical backscatter reflectometry exhibited consistent damage sensitivity, estimating larger crack lengths compared to visual testing by approximately 3 mm and 5 mm, respectively. The optical backscatter reflectometry in uninterrupted tests (dynamic acquisition) showed significantly larger estimations, approximately double those of static ones. This demonstrated its potential to detect possible damage within the adhesive that might not be detected by other methods, as shown previously for quasi-static loading conditions. Its capability in early damage detection under the dynamic regime makes it a valuable tool for continuous monitoring. Furthermore, a comparison of optical backscatter reflectometry's performance in quasi-static, static, and dynamic acquisitions indicated a potentially larger process zone under quasi-static loading, a finding confirmed by the compliance-based beam method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3390/s24237676 | DOI Listing |
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11644967 | PMC |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!