: We evaluated the 3-year effectiveness and safety of XEN45, combined or not with phacoemulsification, in patients from the Italian XEN-Glaucoma Treatment Registry. : Data from glaucoma patients who underwent XEN45 alone or combined with phacoemulsification were analyzed. Changes in intraocular pressure (IOP) and the number of ocular hypotensive medications (OHMs) were tested with repeated measures ANOVA in last observation carried forward (LOCF) and per-protocol (PP) analyses. Complete and qualified success (IOP < 18 mmHg and ≥20% IOP reduction from baseline, without or with OHMs) at 36 months and pre- and intraoperative factors predicting surgery failure were explored using survival analysis and Cox proportional-hazard models. Complications rates were evaluated to assess safety. : The analysis included 239 eyes (239 patients): 144 (60.2%) in the XEN alone and 95 (39.8%) in the XEN+Phaco groups. Overall success was achieved in 164 (68.1%) eyes [113 (68.9%) complete and 51 (31.1%) qualified], without significant differences in success ( = 0.07) and survival rates ( = 0.46) between groups. At the 36th month, the baseline IOP decreased from a median (IQR) of 23.0 (20.0-26.0) to 15.0 (12.0-17.5) mmHg ( < 0.01), with an overall 34.1 ± 20.1% IOP reduction. The mean ± SD number of OHMs decreased from the baseline of 2.7 ± 0.9 to 0.9 ± 1.1 at month 36 ( < 0.01). PP and LOCF analyses were comparable. Neither pre- nor intraoperative factors were significantly predictive of surgery failure. In 91 (38.1%) and 57 (23.8%) of the eyes, at least one postoperative complication occurred early (
Download full-text PDF
Source
http://dx.doi.org/10.3390/jcm13237370 DOI Listing http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11641929 PMC Publication Analysis
Top Keywords
J Clin Med
December 2024
Department of Surgical, Medical, Molecular Pathology and of Critical Care Medicine, University of Pisa, Via Savi 10, 56126 Pisa, Italy.
: We evaluated the 3-year effectiveness and safety of XEN45, combined or not with phacoemulsification, in patients from the Italian XEN-Glaucoma Treatment Registry. : Data from glaucoma patients who underwent XEN45 alone or combined with phacoemulsification were analyzed. Changes in intraocular pressure (IOP) and the number of ocular hypotensive medications (OHMs) were tested with repeated measures ANOVA in last observation carried forward (LOCF) and per-protocol (PP) analyses.
View Article and Find Full Text PDFEye (Lond)
January 2024
Department of Surgical, Medical, Molecular Pathology and of Critical Care Medicine, University of Pisa, Pisa, Italy.
Objectives: To evaluate the 1-year effectiveness and safety of the XEN45, either alone or in combination with phacoemulsification, in glaucoma patients.
Methods: This multicentre, prospective, observational study included consecutive eyes of glaucoma patients from the Italian XEN-Glaucoma Treatment Registry (XEN-GTR) who underwent XEN45 alone or in combination with phacoemulsification, with at least 1 year of follow-up. Surgical success was defined as intraocular pressure (IOP) < 18 mmHg and ≥20% reduction from preoperative IOP, over 1 year of follow-up.
J Clin Med
September 2022
IRCCS Fondazione Bietti, 00198 Rome, Italy.
The Italian XEN Glaucoma Treatment Registry (XEN-GTR) was created to acquire a comprehensive prospective dataset that includes the patient characteristics, intraoperative variables, and postoperative management of glaucoma patients undergoing the XEN gel stent implantation. This was a prospective observational, longitudinal clinical study involving 10 centres throughout Italy. The baseline examination included a comprehensive evaluation of demographic parameters (age, sex, ethnicity, and systemic condition), specific ophthalmological parameters, and quality of life questionnaire score collection.
View Article and Find Full Text PDFJ Glaucoma
July 2021
Department of Surgical, Medical, Molecular Pathology and of Critical Area, University of Pisa, Pisa.
Precis: XEN implant was associated with low endothelial cell density (ECD) reduction. In fact, when combined with phacoemulsification, the reduction in ECD was similar to that expected after phacoemulsification alone.
Purpose: The purpose of this study was to assess the impact of XEN implant, either alone or in combination with phacoemulsification, on ECD.