: Patient compliance is a major concern of hand orthosis in first carpometacarpal osteoarthritis. To address this issue, we established a method for creating a custom-made three-dimensional printed splint based on computed tomography. This prospective study evaluates the usefulness of the three-dimensional printed splint compared with the conventional splint. : A total of 12 hands in nine patients were included. The mean age of the patients was 69 years (range: 58-84). Conventional orthoses were made by prosthetists using molds. Three-dimensional printed orthoses (long and short types) were digitally designed from computed tomography data and created using Fused Deposition Modeling. Subjects were instructed to use three types of orthoses for 2 weeks each. They completed questionnaires that indicated pain, function, percentage of daytime spent using the orthosis, satisfaction score, and discomfort caused by wearing orthoses. : The pain on motion showed an improvement of approximately 20% for all orthoses. There was no significant difference in pain scale, function, percentages of daytime spent using each orthosis, and satisfaction score among the three types of orthoses. Discomfort caused by wearing orthosis was more frequent in conventional orthosis than in 3D-printed orthosis, and there was a significant difference between the conventional type and the long-type 3D-printed orthosis. : This study suggests that 3D-printed splints provide comparable pain relief to conventional splints with reduced discomfort. However, limitations such as small sample size, short follow-up, and reliance on CT imaging highlight the need for further research.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11641956 | PMC |
http://dx.doi.org/10.3390/jcm13237043 | DOI Listing |
Anesth Analg
February 2025
From the Department of Surgical Specialties and Anesthesiology of São Paulo State University (UNESP), Medical School, Botucatu, Brazil.
Background: Proficiency in endotracheal intubation (ETI) is essential for medical professionals and its training should start at medical schools; however, large caseload may be required before achieving an acceptable success rate with direct laryngoscopy. Video laryngoscopy has proven to be an easier alternative for intubation with a faster learning curve, but its availability in medical training may be an issue due to its high market prices. We devised a low-cost 3-dimensionally printed video laryngoscope (3DVL) and performed a randomized trial to evaluate if the intubation success rate on the first attempt with this device is noninferior to a standard commercially available video laryngoscope (STVL).
View Article and Find Full Text PDF3D Print Med
January 2025
Department of Surgical & Interventional Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
Background: Penile implant surgery is the standard surgical treatment for end-stage erectile dysfunction. However, the growing complexity of modern high-tech penile prostheses has increased the demand for more practical training opportunities. The most advanced contemporary training methods involve simulation training using cadavers, with costs exceeding $5,000 per cadaver, inclusive of biohazard fees.
View Article and Find Full Text PDFOral Maxillofac Surg
January 2025
Coastal Ear, Nose & Throat LLC, Neptune, NJ, USA.
Objective: This systematic review and meta-analysis compares the efficacy and complication rate of absorbable versus non-absorbable 3D-printed, patient-customized, maxillofacial implants in facial trauma patients.
Data Sources: A comprehensive search of four databases (PubMed, Scopus, Web of Science, and Cochrane) was conducted.
Methods: A systematic review and single-proportion meta-analysis was conducted employing PRISMA guidelines.
Vet Surg
January 2025
Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada.
Objective: To evaluate the accuracy of ventral slot creation in canine cadavers with a three-dimensional (3D)-printed drill guide compared to the freehand technique.
Study Design: Ex vivo study.
Sample Population: Eight canine cadavers (23.
Brain Spine
December 2024
Department of Neurosurgery, University Hospital of Lausanne and University of Lausanne, 1011, Lausanne, Switzerland.
Introduction: While cadaveric dissections remain the cornerstone of education in skull base surgery, they are associated with high costs, difficulty acquiring specimens, and a lack of pathology in anatomical samples. This study evaluated the impact of a hand-crafted three-dimensional (3D)-printed head model and virtual reality (VR) in enhancing skull base surgery training.
Research Question: How effective are 3D-printed models and VR in enhancing training in skull base surgery?
Materials And Methods: A two-day skull base training course was conducted with 12 neurosurgical trainees and 11 faculty members.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!