A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Corrosion Tendency of S235 Steel in 3.5% NaCl Solution and Drinking Water During Six Months of Exposure. | LitMetric

The pipeline transport industry is constantly developing due to the high efficiency, long life, varied diameters of the pipelines, but a significant problem is the corrosion that occurs because of the corrosive attack of the various environments in which the pipelines are used. This study deals with the ex situ characterizations (optical microscopy, scanning electron microscopy coupled with energy dispersive X-ray analyses, X-ray diffraction analysis, roughness, and Vickers hardness analyses) and the in situ characterizations (gravimetric and electrochemical methods). Samples of steel were tested at immersion time, after 336 h, 672 h, 1344 h, 2016 h, and 4032 h of exposure to a 3.5% NaCl solution and drinking water. The corrosion rate evaluated with the gravimetric method varied between 0.036518 and 0.008993 mm/year in the 3.5% NaCl solution and 0.02834 and 0.034162 mm/year in drinking water. The electrochemical method resulted in an estimated corrosion rate range of 0.097-0.681 mm/year for the 3.5% NaCl solution, and 0.028-0.0472 mm/year for drinking water. The passivation effect, lifetime, and operating limit of the S235JR steel in the tested corrosive environments were studied. The study can provide technical support to increase the service life of S235JR steel and to predict the suitable environment reduce corrosion costs.

Download full-text PDF

Source
http://dx.doi.org/10.3390/ma17235979DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11644010PMC

Publication Analysis

Top Keywords

35% nacl
16
nacl solution
16
drinking water
16
solution drinking
8
situ characterizations
8
steel tested
8
corrosion rate
8
mm/year 35%
8
mm/year drinking
8
s235jr steel
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!