A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Automated Systems with Fluorescence Detection for Metal Determination: A Review. | LitMetric

Automated Systems with Fluorescence Detection for Metal Determination: A Review.

Molecules

Department of Analytical Chemistry, Institute of Chemistry, Faculty of Science, Pavol Jozef Safarik University in Kosice, Moyzesova 11, 040 01 Kosice, Slovakia.

Published: December 2024

Industrialization has led to environmental pollution with various hazardous chemicals including pollution with metals. In this regard, the development of highly efficient analytical methods for their determination has received considerable attention to ensure public safety. Currently, scientists are paying more and more attention to the automation of analytical methods, since it permits fast, accurate, and sensitive analysis with minimal exposure of analysts to hazardous substances. This review discusses the automated methods with fluorescent detection developed for metal determination since 2000. It is evident that flow-injection analysis (FIA) with no preconcentration or with solid-phase preconcentration are predominant compared to liquid-phase preconcentration systems. FIA systems are also more widespread than sequential injection analysis (SIA) systems. Moreover, a significant number of works have been devoted to chromatography-based methods. Atomic fluorescence detectors significantly prevail over molecular fluorescence detectors. It must be highlighted that most of the methods result in good figures of merit and performance characteristics, demonstrating their superiority in comparison with manual systems.

Download full-text PDF

Source
http://dx.doi.org/10.3390/molecules29235720DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11643265PMC

Publication Analysis

Top Keywords

metal determination
8
analytical methods
8
fluorescence detectors
8
methods
5
automated systems
4
systems fluorescence
4
fluorescence detection
4
detection metal
4
determination review
4
review industrialization
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!