A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measurement of non-invasive rectal and ear temperature in inpatients ≥ 18 years old: A cross-sectional comparative study. | LitMetric

Introduction: Body temperature measurement is a fundamental requirement for clinical decisions in nursing care, medical diagnosis, and treatment. Therefore, it is pivotal that body temperature measurements are accurate and precise.

Aims: To test the diagnostic accuracy of an ear temperature screening procedure among adult hospitalized patients. Further aims were to test the precision of the measurements being carried out by trained registered nurses compared with daily routine practice and to investigate patients' preferences for different measurement methods.

Methods: In Aalborg University Hospital, 274 patients were included in a cross-sectional comparative study. Each patient had four temperature measurements and responded to a survey regarding their preference for measurement. Bland-Altman analysis was used to evaluate the difference between ear- and rectal measurements. Sensitivity and specificity were evaluated at different cut-off points.

Results: The ear temperature was 0.1 to 0.2 °C lower than rectal temperature. At a cut-off point at 37.5 °C an ear thermometer is accurate and can be used for screening, while higher cut-off points risk missing patients with fever. There was no significant difference in the mean temperature measured by a trained registered nurse or other staff members and patients. Patients preferred ear measurements to rectal measurements.

Conclusion: The tested ear thermometer is accurate for screening fever in an adult population during hospital admission. Using ear measurement as a screening tool can contribute to a less resource-demanding care activity and a more convenient alternative to rectal measurements in hospitalised patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.zefq.2024.11.005DOI Listing

Publication Analysis

Top Keywords

ear temperature
12
temperature
8
cross-sectional comparative
8
comparative study
8
body temperature
8
temperature measurements
8
trained registered
8
rectal measurements
8
ear thermometer
8
thermometer accurate
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!