We propose a multi-wavelength digital holography based on Kramers-Kronig (KK) relations, introducing a unified angle-multiplexing multi-wavelength KK model to overcome the accuracy and resolution limitations of angle-multiplexing techniques. By linking the real and imaginary parts of the multi-wavelength complex function via the KK relation, the method captures object light waves with the full effective bandwidth from a single interferogram and reference wave intensity. This method greatly improves spectral utilization and measurement accuracy in multi-wavelength interference. We use a three-wavelength multiplexing system to measure the topography of multi-step samples. The results show that our method expands the spectral range more than twice, reduces errors by 39.3%, and improves the peak signal-to-noise ratio and structural similarity index nearly three times compared to the traditional Fourier transform (FT) method. It offers a new, to the best of our knowledge, approach for high-precision multi-wavelength dynamic measurement and has the potential to overcome the limitations of multiplexing technology.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OL.541225 | DOI Listing |
We propose a multi-wavelength digital holography based on Kramers-Kronig (KK) relations, introducing a unified angle-multiplexing multi-wavelength KK model to overcome the accuracy and resolution limitations of angle-multiplexing techniques. By linking the real and imaginary parts of the multi-wavelength complex function via the KK relation, the method captures object light waves with the full effective bandwidth from a single interferogram and reference wave intensity. This method greatly improves spectral utilization and measurement accuracy in multi-wavelength interference.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
February 2025
Department of Chemistry and Industrial Chemistry, University of Pisa, Via G. Moruzzi 13, 56124 Pisa, Italy. Electronic address:
In all experimental sciences, the precision and reliability of quantitative measurements are paramount. This is particularly true when examining the interactions between small molecules and biomolecules/polyelectrolytes, such as DNAs/RNAs, and yet it is overlooked in most publications of thermodynamic binding parameters. This paper presents findings from COST Action 18202 "Network for Equilibria and Chemical Thermodynamics Advanced Research," which assessed the consistency of data derived from the interactions of calf-thymus DNA (CT-DNA) with the fluorescent intercalator ethidium bromide (EB) through spectrofluorimetric titrations.
View Article and Find Full Text PDFMicromachines (Basel)
October 2024
School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China.
Classical frequency-stabilized lasers have achieved high-frequency stability and reproducibility; however, their extensive wavelength spacing limits their utility in various scenarios. This study introduces a novel frequency-stabilized laser scheme that integrates a Fabry-Perot etalon (FPE) with digital control technology and wavelength modulation techniques. The FPE, characterized by multiple transmission peaks at minimal frequency intervals, provides stable frequency references for different lasers, thereby enhancing the system's flexibility and adaptability.
View Article and Find Full Text PDFAnal Methods
October 2024
Faculty of Biosciences and Aquaculture, Nord University, Bodo, Norway.
This study explores a novel approach for in-field speciation of Cr(VI) in various aqueous samples employing nontoxic, MoS quantum dots (QDs) as a fluorescent probe. The proposed fluorimetric method, compatible with commercial instruments, utilizes a portable custom-built fluorimeter equipped with a multi-wavelength LED array. The method seamlessly incorporates digital image analysis, with fluorescence signals recorded by a smartphone for detection and signal analysis.
View Article and Find Full Text PDFJMIR Form Res
June 2024
Movano Inc dba Movano Health, Pleasanton, CA, United States.
Background: Over recent years, technological advances in wearables have allowed for continuous home monitoring of heart rate and oxygen saturation. These devices have primarily been used for sports and general wellness and may not be suitable for medical decision-making, especially in saturations below 90% and in patients with dark skin color. Wearable clinical-grade saturation of peripheral oxygen (SpO) monitoring can be of great value to patients with chronic diseases, enabling them and their clinicians to better manage their condition with reliable real-time and trend data.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!