A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of the performance of a qPCR-based assay for HIV-1 viral load determination. | LitMetric

Evaluation of the performance of a qPCR-based assay for HIV-1 viral load determination.

PLoS One

Department of Anesthesiology, Qilu Hospital of Shandong University, Jinan, Shandong Province, China.

Published: December 2024

Objective: According to the YY/T 1182-2010 standard of the People's Republic of China on nucleic acid amplification test reagents (kits) for medical industry, the accuracy, precision, linear range, and analytic sensitivity of HIV-1 standardized quality control products should be assessed. The Geneway HIV-1 Nucleic Acid Detection Kit from China has been successfully registered with the National Medical Products Administration. Here, we aimed to assess for the first time its detection performance.

Methods: The accuracy, precision, analytic sensitivity, and linearity of the Geneway HIV-1 nucleic acid quantification test kit were analyzed using a series of diluted standard control samples of HIV-1 negative plasma. Clinical plasma samples were collected from 163 HIV-infected patients and 38 HIV-negative patients. The detection performance of the Geneway assay was compared with that of the US FDA-approved COBAS AmpliPrep/COBAS® Taqman® HIV-1 test (Roche), version 2.0, for viral load (VL) monitoring.

Results: The absolute deviation of the assay between the logarithm of the measured concentration and the logarithm of the expected concentration did not exceed ±0.5 logarithmic units. All coefficients of variation (CV%) for the assays were within 5%, indicating good precision in the detection. The linearity of quantitation was excellent (r = 0.999). Overall agreement was observed in 198 of the 201 specimens (98.51%), with a kappa value of 0.953. Bland-Altman analysis revealed an average difference of 0.030 between the two assays, with 95.95% (142/148) of the differences falling within the 95% confidence limits of agreement (-0.50, 0.56). Linear regression results demonstrated a strong linear correlation between the two assays, with a high Pearson correlation coefficient (r = 0.980) and coefficient of determination (R2 = 0.960, p < 0.001).

Conclusions: The Geneway HIV-1 VL assay demonstrated excellent accuracy, precision, analytic sensitivity, and linearity. Compared to the Roche assay, the Geneway assay showed good performance for HIV-1 VL detection, supporting its use in clinical practice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11642942PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0315579PLOS

Publication Analysis

Top Keywords

nucleic acid
12
accuracy precision
12
analytic sensitivity
12
geneway hiv-1
12
hiv-1
8
viral load
8
hiv-1 nucleic
8
precision analytic
8
sensitivity linearity
8
geneway assay
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!