A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Investigating the impact of the effective point of measurement for plane-parallel ionization chambers in clinical proton beams. | LitMetric

AI Article Synopsis

  • This study examines how the placement of plane-parallel ionization chambers affects the calculation of specific factors and beam quality correction factors in proton beams.
  • Monte Carlo simulations were used to analyze six ionization chamber types with different positioning methods, showing significant differences, especially in areas with steep dose gradients.
  • The findings indicate that using the effective point of measurement as recommended by the updated TRS-398 code may introduce systematic errors in the correction factors for these chambers, potentially impacting dosimetry accuracy.

Article Abstract

To investigate the impact of the positioning of plane-parallel ionization chambers in proton beams on the calculation of the chamber-specific factorand, hence, the beam quality correction factorkQ,Q0.Monte Carlo simulations were performed to calculate the chamber-specific factorin monoenergetic proton beams for six different plane-parallel ionization chambers while positioning the chambers with a) their reference point and b) their effective point of measurement accounting for the water equivalent thickness of the entrance window.For all ionization chamber models investigated in this study, the difference inbetween both positioning approaches was larger for steeper dose gradients and bigger differences between the geometrical thickness and water-equivalent thickness of the entrance window. The largest effect was 1.2% for the IBA PPC-05 ionization chamber at an energy of 60 MeV.The positioning of plane-parallel ionization chambers in proton beams has a systematic impact on thefactor. This is especially of relevance for thekQ,Q0factors presented in the recently updated TRS-398 code of practice (CoP) from IAEA. The background is that a positioning with the effective point of measurement is prescribed in TRS-398 CoP, however, all Monte Carlo derived data that have been employed for the update are based on a positioning of the ionization chambers with their reference point. Hence, the updatedkQ,Q0factors for plane-parallel ionization chambers in proton beams are subject to systematic errors that can be as large as 0.5%.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ad9e7cDOI Listing

Publication Analysis

Top Keywords

ionization chambers
24
plane-parallel ionization
20
proton beams
20
effective point
12
point measurement
12
chambers proton
12
ionization
8
positioning plane-parallel
8
chambers reference
8
reference point
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!