Interference of Plasticizers on Plasma Protein Binding Measurements.

AAPS J

Pfizer Worldwide Research and Development, Groton, CT, USA.

Published: December 2024

Accurate measurement of plasma protein binding (PPB) is of critical importance in drug discovery. Methodologies for PPB measurement continue to evolve to address the challenges of highly bound compounds. In order to generate high quality PPB data, it is crucial to not only apply state-of-the-art methods and highly sensitive and selective detectors, but also use high-quality plasma. In this study, we found that plasticizers, leaching from polyvinyl chloride (PVC) plasma storage bags, interfered with drug binding to both human α1-acid glycoprotein (AAG) and human serum albumin (HSA). Several AAG and HSA binding drugs were used to probe the differences in PPB using blood/plasma collected and stored in PVC bags or glass tubes through vacutainers. The results showed that plasma collected using vacutainers into the glass tubes has lower plasma fraction unbound (f) values than those from the PVC bags. The f differences can be as high as 32-fold. Hence, it is recommended to use vacutainers and glass tubes rather than PVC bags, for blood collection and plasma storage. Plasma from animal species collected using polypropylene syringes into polyethylene tubes showed no differences in f from plasma collected using vacutainers into glass tubes. Not all compounds are sensitive to plasticizer interference for PPB. It is therefore important to select appropriate positive controls for f measurement, such as warfarin for HSA and imatinib for AAG, to monitor the quality of plasma and minimize the interference from plasticizers.

Download full-text PDF

Source
http://dx.doi.org/10.1208/s12248-024-00988-6DOI Listing

Publication Analysis

Top Keywords

glass tubes
16
pvc bags
12
vacutainers glass
12
plasma
10
interference plasticizers
8
plasma protein
8
protein binding
8
plasma storage
8
plasma collected
8
collected vacutainers
8

Similar Publications

Studies on Plasmodium falciparum transmission require blood-feeding infectious gametocytes to mosquitoes using standard membrane-feeding assays (SMFAs). SMFAs are routinely performed using electric heating coils or glass membrane feeders connected to a circulatory water bath using tubing and clamps. Each of these approaches is expensive and requires a complex setup, hence restricting the number of assays that can be performed simultaneously.

View Article and Find Full Text PDF

An agarose fluidic chip for high-throughput organoid imaging.

Lab Chip

December 2024

Laboratory of Cell Biology and Histology, Faculty of Biomedical, Pharmaceutical and Veterinary sciences, University of Antwerp, Universiteitsplein 1, Antwerp, Belgium.

Modern cell and developmental biology increasingly relies on 3D cell culture systems such as organoids. However, routine interrogation with microscopy is often hindered by tedious, non-standardized sample mounting, limiting throughput. To address these bottlenecks, we have developed a pipeline for imaging intact organoids in flow, utilizing a transparent agarose fluidic chip that enables efficient and consistent recordings with theoretically unlimited throughput.

View Article and Find Full Text PDF

Root rot affects legumes such as lentil (Lens culinaris subsp. culinaris Medik.) and pea (Pisum sativum L.

View Article and Find Full Text PDF

Enhanced fibrinolysis or hyperfibrinolysis may lead to life-threatening blood loss, while reduced activity may contribute to thrombosis. Euglobulin clot lysis time (ECLT) is a manual method that measures plasma fibrinolytic activity and is considered the gold standard. However, the data on reference interval is scarce and outdated.

View Article and Find Full Text PDF

A rapid and inexpensive 96-well DNA-extraction method from blood using silicon dioxide powder (Glassmilk).

Biol Methods Protoc

October 2024

One Health Research Group, Facultad de Ciencias de la Salud, Universidad de Las Américas, Quito, 170124, Ecuador.

We present a rapid high-throughput DNA extraction method for use with EDTA-anticoagulated blood using silicon dioxide (SiO) powder in a guanidine-HCl solution, hereinafter referred to as "Glassmilk." The method utilizes a 96-well deep-well plate, enabling DNA extraction from 96 samples in under 3 h. The method integrates cell lysis, washing, elution, and DNA storage within the same well, eliminating the need for DNA transfer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!