A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The relationship between air lead and blood lead in a modern US lead-acid battery facility: a longitudinal study. | LitMetric

The relationship between air lead and blood lead in a modern US lead-acid battery facility: a longitudinal study.

J Occup Health

Gradient, One Beacon St., 17th Floor, Boston MA 02108.

Published: December 2024

Objectives: To date, there has been little observational evidence on the relationship between air lead and blood lead at relatively low workplace air lead concentrations. This study improves upon prior studies methodologically and aims to examine this relationship in a modern workplace environment.

Methods: Personal measurements of air lead and blood lead concentrations were collected in a modern lead-acid battery manufacturing facility in the United States. A total of 236 workers and their 2,221 air-blood lead measurement pairs, collected between 2001 and 2021, were included in the statistical analysis. The association between air lead and blood lead was examined using linear mixed-effects models to account for data correlation. Potential confounders adjusted for include age, sex, job department, time trend, tenure, and seasonality.

Results: The workers were mostly (83%) male and on average 29.75 years of age at the first included measurement. Their air lead concentrations ranged from 1 to 50 (arithmetic mean 16.85) μg/m3; blood lead concentrations ranged from 2 to 35 (arithmetic mean 15.47) μg/dL. After adjusting for potential confounders, a 1 μg/m3 increment in air lead was associated with 0.025 (95% confidence interval: 0.005-0.045; marginal, semi-partial ${R}^2$ = 0.002) μg/dL higher blood lead.

Conclusions: The relationship between air lead and blood lead at relatively low workplace air lead concentrations over a long employment period may be very weak, but this needs to be further investigated in future observational studies with quantified lead exposures from non-inhalation routes and non-occupational sources.

Download full-text PDF

Source
http://dx.doi.org/10.1093/joccuh/uiae073DOI Listing

Publication Analysis

Top Keywords

air lead
36
blood lead
24
lead blood
20
lead concentrations
20
lead
17
relationship air
12
modern lead-acid
8
lead-acid battery
8
air
8
lead low
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!