Purpose: To inspect the impact of polyethylene fiber (Ribbond) on the long-span, 3D-printed, interim fixed dental prosthesis regarding fracture strength.
Materials And Methods: A stainless steel platform was fabricated to replicate the partial edentulism for a maxillary four-unit fixed dental prosthesis. The prosthesis was fabricated by a Formlabs SLA 3D printer. The specimens were allocated into four groups of 20 each: experimental reinforced Group A (prosthesis with a slot reinforced with fiber); experimental Group B (prosthesis with a slot filled with 3D-printed material), negative control Group C (prosthesis with a slot); and control Group D (full-contour prosthesis). Fracture strength exams were performed with a universal tester. The fracture patterns were examined. A statistical analysis was conducted using one-way ANOVA and Tukey HSD test.
Results: The control group exhibited a significantly higher mean flexural load (D: 306.32 ± 50.76 N) compared to the other groups (A: 194.37 ± 68.02 N; B: 178.25 ± 42.67 N; and C: 156.68 ± 29.73 N; [P < .001]). No differences were identified among Groups A, B, and C. The fracture pattern differed between the nonreinforced Groups B, C, and D and reinforced Group A, with catastrophic failure observed in the nonreinforced group and unseparated failure observed in the reinforced group.
Conclusions: The study findings demonstrate that the incorporation of Ribbond in 3D-printed, interim fixed dental prostheses does not significantly enhance their fracture strength. However, it does lead to a noticeable change in the fracture behavior, shifting from a complete failure to an incomplete fracture pattern.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.11607/ijp.9203 | DOI Listing |
Cureus
November 2024
School of Dental Sciences, Universiti Sains Malaysia, Kota Bharu, MYS.
Background and objective Applying different hygiene tools for implant maintenance alters surface configurations, impacting bacterial adhesion on titanium implant surfaces and potentially leading to peri-implant diseases. This study aimed to assess the alterations in surface topography of titanium implant fixtures after utilizing hygiene instruments such as airflow; erbium, chromium-doped: yttrium, scandium, gallium, and garnet (Er, Cr: YSGG) laser; and titanium brush, under scanning electron microscope (SEM) observation. Materials and methods We employed an experimental laboratory study design for this research, involving 20 MegaGen ST titanium implant fixtures (MegaGen Implant Co.
View Article and Find Full Text PDFAsian Pac J Cancer Prev
December 2024
Department of Periodontology, HKDET'S Dental College, Hospital and Reaserch Institute, Humnadad, Karnataka, India.
Objectives: Oral submucous fibrosis (OSMF) is a potentially malignant disorder (PMD) characterized by a high rate of malignant transformation (MT). OSMF exhibits atrophic epithelium yet has a high proliferation rate. Both p53 and Ki67 are nuclear proteins associated with cell proliferation, detectable in the early stages of oral cancer (OC).
View Article and Find Full Text PDFSci Rep
December 2024
Clean Energy Technologies Research Institute (CETRI), Process Systems Engineering, Faculty of Engineering & Applied Science, University of Regina, 3737 Wascana Parkway, Regina, SK, S4S 0A2, Canada.
Real-world emissions of particulate matter (PM) and smoke opacity were studied for an older-model diesel pickup truck during four types of driving tests, namely fixed-point test, snap-acceleration test, road test, and hill road test (uphill/downhill). A portable emissions measurement system (PEMS) and an opacimeter were used to measure real-time concentrations of PM and smoke opacity, respectively, and simultaneously. Correlation analysis showed a significant positive association between PM and opacity, suggesting the feasibility of using an opacimeter to estimate PM mass emissions from diesel vehicles.
View Article and Find Full Text PDFJ Funct Biomater
November 2024
Department of Occlusion, Fixed Prosthodontics and Dental Materials, School of Dentistry, Federal University of Uberlandia, Uberlandia 38405-320, Minas Gerais, Brazil.
This study aimed to evaluate the scanning time and marginal fit of CAD/CAM crowns fabricated using different intraoral scanning systems (IOS) (O1-Omnicam 1.0, O2-Omnicam 2.0, PS-Primescan).
View Article and Find Full Text PDFDent J (Basel)
December 2024
Faculty of Medicine and Health Sciences, University of Barcelona, 08907 Barcelona, Spain.
Introduction: In recent years, erbium-doped yttrium aluminum garnet (Er:YAG) and erbium, chromium/yttrium-scandium-gallium-garnet (Er,Cr:YSGG) lasers have been introduced as another possibility to perform less-invasive flapless (FL) crown-lengthening (CL) procedures.
Objectives: The aim of this review is to describe the outcomes and complications of this approach.
Materials And Methods: A literature review was conducted to retrieve clinical studies and case reports that analyze different variables related to laser-assisted flapless crown lengthening and report their outcomes in terms of gingival margin level stability (GMLS), and postoperative complications.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!