Knowledge among clinical personnel on the impact of hemolysis using blood gas analyzers.

Clin Chem Lab Med

Department of Clinical Biochemistry, Odense University Hospital, Odense, Denmark.

Published: December 2024

Objectives: In the light of a rapidly increasing use of POCT blood gas testing, where tests and interpretation are performed by non-laboratory personnel, the objective was to investigate the knowledge among personnel in the Nordic countries using blood gas analyzers with focus on the interference from hemolysis.

Methods: Information was obtained from a self-developed, pre-tested online questionnaire. The questions covered demographic information about the respondents and specific questions on handling of and knowledge about blood gas analyses and the impact of hemolysis. The questionnaire was distributed by e-mail to relevant colleagues on behalf of the Nordic preanalytical scientific working group under the Nordic Federation of Clinical Chemistry.

Results: A total of 117 respondents completed the questionnaire. 62.7 % respondents both used the analyzer and interpreted the results. 59.6 % respondents did not know to which degree the blood gas analyzer can identify hemolysis. 4.4 % answered that all levels or high levels of hemolysis can be detected. 3.9 % considered the result valid despite hemolysis if it is released from the instrument. 73.7 % of all respondents knew that hemolysis alters potassium measurements, while knowledge about the effect on PaO and bicarbonate measurements were more divergent.

Conclusions: The knowledge about blood gas analyzers with focus on the interference from hemolysis is sparse among non-laboratory personnel using the blood gas analyzers. This emphasizes the need for better education and competence management, which perhaps is even more important for these analyses than for other point-of-care tests.

Download full-text PDF

Source
http://dx.doi.org/10.1515/cclm-2024-1018DOI Listing

Publication Analysis

Top Keywords

blood gas
24
gas analyzers
16
impact hemolysis
8
non-laboratory personnel
8
analyzers focus
8
focus interference
8
knowledge blood
8
hemolysis
7
gas
7
blood
6

Similar Publications

Evaluating the effectiveness of handheld ultrasound in primary blast lung injury: a comprehensive study.

Sci Rep

January 2025

Department of Military Traffic Injury Prevention and Control, Daping Hospital, Army Medical University, No. 10 Changjiang Branch Road, Yuzhong District, Chongqing, 400042, China.

The incidence of blast injuries has been rising globally, particularly affecting the lungs due to their vulnerability. Primary blast lung injury (PBLI) is associated with high morbidity and mortality rates, while early diagnostic methods are limited. With advancements in medical technology, and portable handheld ultrasound devices, the efficacy of ultrasound in detecting occult lung injuries early remains unclear.

View Article and Find Full Text PDF

Introduction: Qualitative and quantitative testing of ethanol in samples is an important analytical procedure that provides accurate, precise, and reliable results. Given the complexity of the issue, obtaining a realistic picture of lifelong alcoholemia requires supporting blood ethanol findings with analyses of alternative samples, primarily vitreous humor (VH).

Objective: The objective of this study was to develop and validate a headspace gas chromatography with flame ionization detection (HS/GC-FID) method for determining ethanol concentration in VH.

View Article and Find Full Text PDF

Introduction: Opportunistic infections (IO) are infections of microbiota (fungi, viruses, bacteria, or parasites) that generally do not cause disease but turn into pathogens when the body's defense system is compromised. This can be triggered by various factors, one of which is due to a weakened immune system due to Diabetes Mellitus (DM), which increases the occurrence of opportunistic infections, especially in the oral cavity. Fungal (oral candidiasis) and viral (recurrent intraoral herpes) infections can occur in the oral cavity of DM patients.

View Article and Find Full Text PDF

pH remains the most important chemical parameter and must be monitored for positive outcomes in areas as different as cheese making and fertilisation (IVF). Where blood gas analysers enable patient monitoring, starter cultures in cheese manufacturing are still monitored using conventional pH electrodes. Here, we present a homogeneous multiwell plate sensor for monitoring pH, with the same sensitivity as a pH electrode.

View Article and Find Full Text PDF

miR-18a-5p/PXR/SREBP2 Was Involved in MAFLD Associated With Methyl Tert-Butyl Ether Among Petrol Station Workers.

Liver Int

February 2025

Department of Occupational Health and Environmental Health, School of Public Health, Capital Medical University, Beijing, China.

Background: Metabolic associated fatty liver disease (MAFLD), previously defined as non-alcoholic fatty liver disease (NAFLD), has been shown to be closely related to many environmental pollutants. Lately, we found methyl tert-butyl ether (MTBE), a new environmental pollutant, could increase NAFLD risk in American adults, which still needs more population epidemiological studies to verify, and its pathogenic mechanism is not yet clear.

Methods: We conducted a cross-sectional study among petrol station workers, diagnosed their MAFLD according to internationally recognised diagnostic criteria, assessed the potential association of MTBE exposure with MAFLD risk, and explored the miR-18a-5p/PXR/SREBP2 pathway as possible pathogenic mechanisms in male Wistar rats and HepaRG cells treated with MTBE.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!