SAFT imaging for high-density polyethylene using quasi-static components of ultrasonic longitudinal waves.

Ultrasonics

College of Aerospace Engineering, Chongqing University, Chongqing 400044, China. Electronic address:

Published: November 2024

AI Article Synopsis

  • High-density polyethylene (HDPE) is widely used in various industries, including nuclear power, due to its strong properties, but traditional ultrasound imaging faces challenges due to HDPE's thickness and high acoustic attenuation.
  • This study introduces a new defect imaging method that combines quasi-static components (QSC) with high-frequency wave propagation, allowing better detection of defects in thick HDPE while overcoming limitations of both high and low-frequency ultrasound methods.
  • Experimental results demonstrate that this innovative approach significantly outperforms standard linear ultrasound imaging techniques in identifying defects within HDPE materials, enhancing its potential applications in industries reliant on this material.

Article Abstract

High-density polyethylene (HDPE) is extensively utilized across various industries, including nuclear power, primarily for its exceptional properties. However, there are challenges with traditional linear ultrasound imaging systems due to the significant thicknesses and the highly attenuative of HDPE. High-frequency carrier waves can offer better imaging resolution but also suffer higher acoustic attenuation, which limits the propagation distance of primary longitudinal waves (PLW) and makes it difficult to detect defects within thick HDPEs. On the other hand, using low-frequency PLW for defect detection presents challenges in resolution despite lower attenuation and longer propagation distances. This study proposes a defect imaging method for HDPEs by using quasi-static components (QSC) generated along with high-frequency fundamental wave propagation because of the nonlinear effect. The QSC has the advantage of low attenuation because its carrier frequency is zero, which can propagate a long distance in a high acoustic attention medium like HDPE. A nonlinear ultrasonic imaging approach combining the QSC and synthetic aperture focusing technique is proposed for defect imaging in HDPEs. Experiments on HDPEs with single and multiple defects are conducted to verify the performance of the proposed method. For comparison, the imaging results using traditional linear ultrasounds with high (2.5 MHz) and low (0.5 MHz) carrier frequencies are also provided. The results show the proposed method has better imaging performance over traditional linear ultrasound imaging methods for defect defections in high acoustic attention medium.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultras.2024.107534DOI Listing

Publication Analysis

Top Keywords

traditional linear
12
high-density polyethylene
8
quasi-static components
8
longitudinal waves
8
linear ultrasound
8
imaging
8
ultrasound imaging
8
better imaging
8
defect imaging
8
high acoustic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!