A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Apportioning radon contamination sources in underground spaces using a grey-box model. | LitMetric

Apportioning radon contamination sources in underground spaces using a grey-box model.

J Hazard Mater

Department of Earth and Environmental Sciences, Korea University, 145, Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea. Electronic address:

Published: November 2024

AI Article Synopsis

  • The study addresses the need for effective radon management indoors due to its carcinogenic risks, identifying both gaseous and aqueous radon as main sources.
  • Researchers developed a grey-box model that combines physical theories with data to better understand and apportion indoor radon sources.
  • Results show that indoor radon levels were significantly higher than EPA recommended limits, with aqueous radon degassing identified as the primary source, suggesting that the grey-box model could enhance mitigation strategies.

Article Abstract

The management of radon in indoor environments is essential owing to its carcinogenic risk, with the main sources being gaseous radon from advection and aqueous radon from degassing. However, methods for apportioning indoor radon sources are limited, due to gaps between preliminary physical information and site-specific measurement. This study proposes a method for apportioning sources utilizing a grey-box model that integrates physical theories with data information. Monitoring of indoor air conditioning was conducted and a grey-box model for indoor radon contamination was established using a signal processing system and a physical-based model. Based on the optimized grey-box model, sources of indoor radon were apportioned. The average radon concentration during the monitoring period was 1104 Bq/m³, which was 7.5 times higher than 148 Bq/m³ , the action level recommended by EPA. The grey-box model showed good performance for predicting indoor radon concentrations. Degassing of aqueous radon was identified as the main source of indoor radon. The estimations provided by the grey-box model showed its potential to assess the contribution of each transport mechanism. Apportioning sources through grey-box modeling is a promising method for developing optimized mitigation strategies and bridging data gaps between the preliminary conceptual site model and site investigation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhazmat.2024.136707DOI Listing

Publication Analysis

Top Keywords

grey-box model
24
indoor radon
20
radon
10
radon contamination
8
model
8
aqueous radon
8
gaps preliminary
8
apportioning sources
8
grey-box
7
indoor
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!