A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Calibration-free disposable electrochemical sensor with co-facing electrodes for viscosity monitoring of plasma samples. | LitMetric

Plasma viscosity measurement is crucial in clinical diagnostics, providing insights into blood rheology and health status. Traditional methods, such as capillary and rotational viscometers, require large sample volumes and complex calibration. This study presents a novel disposable electrochemical sensor with co-facing electrodes for viscosity monitoring of plasma samples. The sensor independently determines the diffusion coefficient (D) of the electroactive test molecule ferrocyanide, eliminating the need for calibration curves. This enables the subsequent calculation of the solution's viscosity via the Stokes-Einstein relation. The sensor's performance was validated against a standard quartz-crystal microbalance method, demonstrating high accuracy and reliability. It maintained consistent measurements despite the presence of common electroactive plasma interferents such as ascorbic acid (≤160 μM), dopamine (<9.0 nM), uric acid (<1.0 mM), and urea (<15.6 mM). Although these interferents impacted D at concentrations exceeding twice the maximum levels typically present in plasma, the sensor exhibited robust performance under normal physiological conditions and standard interferent concentrations. The sensor offers rapid response times of less than 20 s, requires only 7 μL of sample, and is cost-effective, making it suitable for point-of-care applications. Bland-Altman plot analysis confirmed its precision, showing a mean difference of 0.00877 and narrow limits of agreement compared to the standard method used.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2024.127290DOI Listing

Publication Analysis

Top Keywords

disposable electrochemical
8
electrochemical sensor
8
sensor co-facing
8
co-facing electrodes
8
electrodes viscosity
8
viscosity monitoring
8
monitoring plasma
8
plasma samples
8
calibration-free disposable
4
viscosity
4