Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Diagnosis of non-small cell lung cancer (NSCLC) currently relies on imaging; however, these methods are not effective for detecting early stage disease. Investigating blood-based protein biomarkers aims to simplify the diagnostic process and identify disease-associated changes before they can be seen by using imaging techniques. In this study, plasma and frozen whole blood cell pellets from NSCLC patients and healthy controls were processed using both classical and novel techniques to produce a unique set of four sample types from a single blood draw. These samples were analyzed using 12 immunoassays and liquid chromatography-mass spectrometry to collectively screen 3974 proteins. Analysis of all fractions produced a set of 522 differentially expressed proteins, with conventional blood analysis (proteomic analysis of plasma) accounting for only 7 of the total. Boosted regression tree analysis of the differentially expressed proteins produced a panel of 13 proteins that were able to discriminate between controls and NSCLC patients, with an area under the ROC curve (AUC) of 0.864 for the set. Our rapid and reproducible (<10% CV for technical replicates) blood preparation and analysis methods enabled the production of high-quality data from only 30 μL of complex samples that typically require significant fractionation prior to proteomic analysis. With our methods, almost 4000 proteins were identified from a single fraction over a 62.5 min gradient by LC-MS/MS.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.jproteome.4c00829 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!