Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: The present retrospective study aimed to determine the relationship between the secondary implant stability quotient and different parameters related to an oxidized implant.
Methods: A total of 135 patients (305 oxidized implants) were included. Implant-related factors (length, diameter, surgical and loading protocols, grafting, insertion torque, and primary stability) were used for comparisons and linear regression analyses, using secondary ISQ as the dependent variable.
Results: At the patient level, the mean time from implantation to secondary ISQ registration was 20.3 ± 29 weeks, and the mean secondary ISQ was 77.30 ± 7.22. The ISQ did not reveal significant differences regarding implant lengths, loading protocol, and simultaneous grafting. In contrast, platform diameters (3.5, 4.3, and 5.0), surgical protocols (one stage versus two stages), insertion torque (<35 Ncm versus >35 Ncm), and primary stability (achieved versus not achieved) all revealed significant secondary ISQ differences. Nevertheless, the regression analysis demonstrated that the platform diameter was the only variable significantly and positively predicted the secondary ISQ. Similar findings were found with the implant level analysis.
Conclusions: Among different implant- and protocol-related parameters, the platform diameter of the oxidized implant appears to be the only significant predictor of high secondary ISQ values at the time of superstructure connection.