A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The relationship between the secondary implant stability quotient and oxidized implant-related factors: A retrospective study. | LitMetric

Objective: The present retrospective study aimed to determine the relationship between the secondary implant stability quotient and different parameters related to an oxidized implant.

Methods: A total of 135 patients (305 oxidized implants) were included. Implant-related factors (length, diameter, surgical and loading protocols, grafting, insertion torque, and primary stability) were used for comparisons and linear regression analyses, using secondary ISQ as the dependent variable.

Results: At the patient level, the mean time from implantation to secondary ISQ registration was 20.3 ± 29 weeks, and the mean secondary ISQ was 77.30 ± 7.22. The ISQ did not reveal significant differences regarding implant lengths, loading protocol, and simultaneous grafting. In contrast, platform diameters (3.5, 4.3, and 5.0), surgical protocols (one stage versus two stages), insertion torque (<35 Ncm versus >35 Ncm), and primary stability (achieved versus not achieved) all revealed significant secondary ISQ differences. Nevertheless, the regression analysis demonstrated that the platform diameter was the only variable significantly and positively predicted the secondary ISQ. Similar findings were found with the implant level analysis.

Conclusions: Among different implant- and protocol-related parameters, the platform diameter of the oxidized implant appears to be the only significant predictor of high secondary ISQ values at the time of superstructure connection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11620092PMC
http://dx.doi.org/10.1016/j.heliyon.2024.e39156DOI Listing

Publication Analysis

Top Keywords

secondary isq
24
relationship secondary
8
secondary implant
8
implant stability
8
stability quotient
8
implant-related factors
8
retrospective study
8
insertion torque
8
primary stability
8
platform diameter
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!