Super-resolved three-dimensional near-field mapping by defocused imaging and tracking of fluorescent emitters.

Nanophotonics

School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea.

Published: December 2022

Near-field optics is essential in many nanotechnology applications, such as implementing sensitive biosensing and imaging systems with extreme precision. Understanding optical near-fields at the nanoscale has so attracted the considerable research interest, which use a variety of analytical approaches, most notably near-field scanning microscopy. Here, we show defocused point localization mapped accumulation (DePLOMA), which can overcome many weaknesses of conventional analytical methods. DePLOMA is based on imaging fluorescence emitters at an out-of-focal plane. The acquisition, collection, and accumulation of the position and fluorescence intensity of emitters moving above nanostructures can generate three-dimensional near-field maps of light distribution. The idea enables super-resolution liquid-phase measurements, as demonstrated by reconstruction of near-field created by nanoslits with a resolution determined by emitter size. We employed fluorescent emitters with a radius of 50 and 100 nm for confirmation. The axial resolution was found to be enhanced by more than 6 times above that of diffraction-limited confocal laser scanning microscopy when DePLOMA was used.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11501887PMC
http://dx.doi.org/10.1515/nanoph-2022-0546DOI Listing

Publication Analysis

Top Keywords

three-dimensional near-field
8
fluorescent emitters
8
scanning microscopy
8
near-field
5
super-resolved three-dimensional
4
near-field mapping
4
mapping defocused
4
defocused imaging
4
imaging tracking
4
tracking fluorescent
4

Similar Publications

Ultrasonic sensors based on backscattering principles have been developed for various applications involving arbitrary or random scatterer distributions. Although the theory of multiple scattering of waves is well-established, it has not been thoroughly explored in these applications. This work presents a feasible and simplified three-dimensional scattering model to predict the transient response generated by a set of rods positioned in the near field of a 1 MHz water-coupled ultrasonic transducer.

View Article and Find Full Text PDF

This study employed numerical simulation to investigate the dynamic response characteristics of open-web girders subjected to proximity blast loading and to compare these characteristics with those of solid-web girders. The research utilized the Coupled Eulerian-Lagrangian (CEL) method for simulation, effectively combining the advantages of both Eulerian and Lagrangian approaches. This method mitigated issues related to mesh distortion while accurately modeling the damage inflicted by blast loads on the structures.

View Article and Find Full Text PDF

Terahertz scanning near-field optical microscopy for biomedical detection: Recent advances, challenges, and future perspectives.

Biotechnol Adv

December 2024

Center of Super-Resolution Optics and Chongqing Engineering Research Center of High-Resolution and Three-Dimensional Dynamic Imaging Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, China; Chongqing School, University of Chinese Academy of Sciences, Chongqing 400714, China. Electronic address:

Terahertz (THz) radiation is widely recognized as a non-destructive, label-free, and highly- sensitive tool for biomedical detections. Nevertheless, its application in precision biomedical fields faces challenges due to poor spatial resolution caused by intrinsically long wavelength characteristics. THz scanning near-field optical microscopy (THz-SNOM), which surpasses the Rayleigh criterion, offers micrometer and nanometer-scale spatial resolution, making it possible to perform precise bioinspection with THz imaging.

View Article and Find Full Text PDF

Three-Dimensional Visualization of Chiral Nano-Optical Field around Gold Nanoplates via Scanning Near-Field Optical Microscopy.

Nano Lett

December 2024

Department of Chemistry and Biochemistry, School of Advanced Science and Engineering, Waseda University, 3-4-1, Okubo, Shinjuku, Tokyo, 169-8555, Japan.

In this study, we examine the three-dimensional chiral optical field in the vicinity of a gold nanoplate using aperture-type scanning near-field optical microscopy. Near-field imaging indicates that the chiral optical field shows a unique spatial distribution and depends on the incident polarization. We also evaluate the modal dependence of chiral optical fields, which reveals that the plasmon mode with E symmetry contributes substantially to the chiral optical field while that with A symmetry contributes little because of the high spatial symmetry.

View Article and Find Full Text PDF

Plasmonic-nanowire near-field beam analyzer.

Nanophotonics

March 2024

Laboratory of Integrated Opto-Mechanics and Electronics, School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.

Article Synopsis
  • Experimental near-field analysis of output beams from micro/nano-waveguides is crucial for designing nanophotonic devices, yet it hasn’t been demonstrated until now.
  • The study introduces a plasmonic-nanowire beam analyzer using a single Au nanowire to scan near-field distributions, achieving a resolution of 190 nm and a collection efficiency of about 47.4%.
  • This novel approach enables the first 3D characterization of spatial distributions from a metal nanowire output beam and showcases the ability to analyze complex multimodes in large nanoribbons, indicating potential applications in nanolasers and biosensing.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!