A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comprehensive and Sensitive Analysis of Total PAEs Using a Label-Free Zero-Voltage Photoelectrochemical Biosensor. | LitMetric

The sensing of phthalate esters (PAEs) is vital for people's health and environmental protection. This study aimed to develop a highly sensitive and selective photoelectrochemical (PEC) biosensor for PAEs analysis in complex samples. The biosensor is based on a CdS nanoparticle/TiO nanotube (CdS NP/TiO NT) electrode substrate and a truncated PAEs aptamer (PAEs-apt). By exploiting spatial variations in the potential resistance of the sensing interface, the biosensor achieved superior sensitivity in determining the concentration of PAEs compared to the SELEX aptamer. It exhibited a linear correlation in the range of 0.005 to 1 ng/mL with a detection limit of 1.67 ng/L. Furthermore, the biosensor displayed excellent selectivity for PAEs, with an analysis error factor below 0.277 when the concentration of interfering species was 100 times that of the target. The high performance of the biosensor was attributed to the excellent photoelectronic properties of CdS NPs/TiO NTs, high density of PAEs-apt for PAEs, high affinity of PAEs-apt for PAEs, and specific recognition of PAEs. Notably, this PEC biosensor could be used for the PAEs assay in urine and water samples, providing a sensitive and simple analytical method for detecting the same class of compounds with similar chemical structures in complex samples.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.4c16714DOI Listing

Publication Analysis

Top Keywords

paes
10
pec biosensor
8
biosensor paes
8
paes analysis
8
complex samples
8
paes-apt paes
8
biosensor
7
comprehensive sensitive
4
sensitive analysis
4
analysis total
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!