AI Article Synopsis

  • Robot-assisted techniques in stereotactic brain biopsies have improved safety and precision, making them a viable option for tissue diagnosis of intracranial lesions.
  • A meta-analysis of 27 studies involving 2605 patients showed a high diagnostic yield of 98%, with a mean operative time of 52.45 minutes and a low risk of complications, including 6% for postoperative hemorrhage.
  • Overall, the study indicates that robot-assisted biopsies offer significant advantages in terms of effectiveness and reduced complications, solidifying their role in the future of neurosurgical diagnostics.

Article Abstract

Introduction: Intracranial lesions often require tissue diagnosis through stereotactic biopsies. Originating in the 1970s, this technique has progressed, but limitations and risks persist. Recently, robot-assisted techniques have made strides, providing the potential for safer and more precise procedures. This study assesses the effectiveness and safety of robot-assisted brain biopsies.

Methods: Following Cochrane and PRISMA guidelines, PubMed, Embase, and Web of Science were searched for publications up to July 2024. Outcomes assessed included neurological deficits, hemorrhage, mortality, target point error, operative time, and length of stay. Data extraction and bias assessment were conducted using standardized methods, and statistical analysis was performed using R software.

Results: In this meta-analysis, 27 papers were included, involving 2605 patients. The gender distribution was 1448 males to 1141 females. The mean error in millimeters for the entry point error was 1.04 (95%CI: 0.72-1.37), while the target point error was 1.08 (95%CI: 0.49-1.66). The mean operative time was 52.45 min (95%CI: 37.83-67.07). Diagnostic yield had an estimated rate of 98% (95%CI: 97-98%; I²=31%). The length of hospital stay was 4.64 days (95%CI: 3.13, 6.14), from admission to discharge. The postoperative hemorrhage had an estimated risk of 6% (95%CI: 4-9%; I²=71%), while for transient neurological deficits, it was 4% (95%CI: 2-6%; I²=60%). Finally, the death related to the procedure was found to have an estimated risk of 0% (95%CI: 0-0%; I²=0%).

Conclusion: Our study found that the diagnostic yield of stereotactic brain biopsy, especially with robotic assistance, has proven to be highly effective. Robot-assisted biopsies also seems to reduce operative times and demonstrate high precision with low entry point error and target point error. Additionally, complication rates appear to be relatively low, and the average hospital stay is favorably short, underscoring the advantages of robotic assistance in stereotactic brain biopsy procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10143-024-03122-4DOI Listing

Publication Analysis

Top Keywords

point error
20
stereotactic brain
12
brain biopsy
12
target point
12
neurological deficits
8
operative time
8
entry point
8
95%ci
8
diagnostic yield
8
hospital stay
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!