Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To evaluate isokinetic dynamometer reliability for isometric assessment of plantar flexor (PF) strength.
Design: Cross-sectional.
Setting: Testing by the same physiotherapist twice during a first session (repeatability) and once during a second session (reproducibility).
Participants: Twenty-two healthy subjects (44 ankles, 11 men/11 women).
Main Outcome Measures: Isometric PF peak torque, with and without body mass normalization, at 0° and +20° of plantar flexion. Measurement reliability was evaluated using intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimal detectable change (MDC).
Results: Without normalization, measurement repeatability was excellent at 0° of plantar flexion (ICC, 0.94; SEM, 6.6%; MDC, 18.4%) compared with good repeatability at +20° (ICC, 0.85; SEM, 11.1%; MDC 30.6%). Measurement repeatability following normalization was good at 0° (ICC, 0.88; SEM, 5.2%; MDC, 14.4%) and +20° (ICC, 0.79; SEM, 10.2%; MDC, 28.1%). While reproducibility was good at 0° with normalization (ICC, 0.84; SEM, 5.9%; MDC, 16.3%) or excellent without (ICC 0.92; SEM 7.5%; MDC, 20.8%), it was moderate at +20° with normalization (ICC 0.71; SEM 11.3%; MDC, 31.3%) or good without (ICC 0.78; SEM 13.0%; MDC, 36.1%).
Conclusion: The reliability of PF maximal isometric strength is good/excellent at 0° of plantar flexion but moderate/good at +20°.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ptsp.2024.11.001 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!