Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Hemozoin (HZ, a malarial pigment) is an insoluble crystalline byproduct formed during the intraerythrocytic breakdown of hemoglobin by some blood-feeding parasites, such as . It consists of polymerized iron-porphyrin molecular units linked by carboxylic bonds. Due to the rigid molecular structure, studying the electron transfer activity of HZ is challenging. In this work, we report the development of a redox-active HZ-functionalized multi-walled carbon nanotube (MWCNT) modified glassy carbon electrode (GCE/MWCNT@HZ-redox). Here, HZ-redox refers to the redox-active form of hemozoin. This electrode is designed to study the electron transfer activity and mimic the peroxidase enzyme's ability to mediate hydrogen peroxide reduction in a neutral pH solution. The modified electrode exhibited a stable and well-defined redox peak at -0.385 V Ag/AgCl in N-purged PBS (pH 7.0) with a surface excess value of 1.64 × 10 mol cm. The MWCNT@HZ-redox was characterized using Raman spectroscopy, FT-IR, and FESEM techniques. This biomimicking electrode showed excellent electrocatalytic reduction of HO using cyclic voltammetry. Batch-injection analysis coupled with a screen-printed electrode demonstrated the electroanalytical performance for HO sensing. The electrode exhibited a linear concentration range of 50-300 μM, with a sensitivity of 21 μA μM and a detection limit of 220 nM. As a bioanalytical application, we successfully demonstrated the monitoring of HO within the reactive oxygen species of HCT-116 colon cancer cells under stimulated conditions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/d4tb01902d | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!