Purpose: The objective of the current study is to introduce a proposed method and evaluate its efficacy using the greater trochanter (GT) tip rather than the lesser trochanter (LT) as an anatomical landmark to reduce leg length discrepancy (LLD) during performance of hip arthroplasty.

Materials And Methods: Thirty-two patients who underwent hip arthroplasty were divided according to the GT group (n=17) and the LT control group (n=11); four patients were excluded. LLD was determined by assessing the vertical lengths parallel to the line connecting the lower margin of the teardrop to the most prominent part of the LT on a standing anteroposterior pelvic X-ray taken 30 days after the procedure. The mean and median LLD of the two groups were compared. Analysis of planning for femoral stem depth insertion and postoperative results was also performed.

Results: No significant differences in characteristics including age, sex, or body mass index were observed between the two groups. However, the type of arthroplasty differed significantly between groups (=0.016). The mean postoperative LLD was significantly smaller in the GT group compared with the control group (=0.004). The results of linear regression of femoral stem depth showed a significant association between intraoperative planning and postoperative measurement (t=2.705, =0.672, =0.016).

Conclusion: Preoperative measurement in determining femoral stem depth insertion using the GT tip as an anatomical reference can effectively minimize LLD in patients who underwent hip arthroplasty.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11638752PMC
http://dx.doi.org/10.5371/hp.2024.36.4.302DOI Listing

Publication Analysis

Top Keywords

hip arthroplasty
12
femoral stem
12
stem depth
12
greater trochanter
8
trochanter anatomical
8
anatomical reference
8
leg length
8
length discrepancy
8
patients underwent
8
underwent hip
8

Similar Publications

Purpose: Identifying muscles linked to postoperative physical function can guide protocols to enhance early recovery following total hip arthroplasty (THA). This study aimed to evaluate the association of preoperative pelvic and thigh muscle volume and quality with early physical function after THA in patients with unilateral hip osteoarthritis (HOA).

Methods: Preoperative Computed tomography (CT) images of 61 patients (eight males and 53 females) with HOA were analyzed.

View Article and Find Full Text PDF

[What should be considered in the case of previous operations or injections prior to hip and knee replacement?].

Orthopadie (Heidelb)

January 2025

Klinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Freiburg, Medizinische Fakultät, Albert-Ludwigs-Universität Freiburg, Freiburg, Deutschland.

Background: Patients who have had prior injections, surgeries such as arthroscopies, and have existing osteosynthetic implants in the hip and knee have an increased risk of periprosthetic infections when undergoing hip (THA) or total knee arthroplasty (TKA).

Osteosynthesis: For patients with osteosynthetic implants in the knee joint, a two-stage procedure (implant removal followed by TKA) is recommended based on the available literature and the high colonization rates. A two-stage procedure is also recommended for patients with hip implants.

View Article and Find Full Text PDF

Total hip arthroplasty (THA) is a widely performed surgical procedure in the United States, but disparities in THA outcomes related to hospital-level factors, such as safety-net burden, are underexplored. This study expands on previous research by analyzing multicenter, multistate data from 2015 to 2020 to investigate the impact of hospital safety-net burden-defined as the proportion of services billed to Medicaid and uninsured patients-on THA outcomes. This study is a retrospective analysis using data from the State Inpatient Databases for Florida, Kentucky, Maryland, New York, Washington, New Jersey, and North Carolina.

View Article and Find Full Text PDF

Background: Reducing unnecessary emergency department (ED) visits following joint arthroplasty is an important goal. Literature suggests 30-day visit rates range between 4% and 15%, with only 20%-25% of these admitted for care. Low admissions suggest an opportunity to reduce unnecessary postarthroplasty ED visits.

View Article and Find Full Text PDF

Mid-term Clinical and Radiographic Outcomes of the Actis Total Hip System: A Retrospective Study.

Cureus

January 2025

Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, JPN.

Introduction Implant technology for total hip arthroplasty (THA) was developed to improve hip function and patient satisfaction. Actis (DePuy Synthes, Warsaw, IN, USA) is a short fit-and-fill titanium stem, with a medial-collared and triple-taper (MCTT) geometry, that is fully coated with hydroxyapatite (HA). We evaluated the radiographic and clinical outcomes of the Actis Total Hip System during a mean follow-up of five years.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!