Background: A crucial aspect of contemporary dental implant research is modifying implant microdesign to achieve early and robust osseointegration. This study describes a new facile subtraction approach for microdesign modification of titanium implants using akali-hydrothermal followed by ion-exchange reaction (AHIE) in a salt solution, and compares osseointegration performance to machined titanium alloy (negative control) implants.
Methods: The morphology, wettability, and roughness of the implant surfaces were evaluated. Twenty-four cylinders (two types/side) were inserted into the right and left mandibles of six Bengal goats in opposite order. The implant-bone interface was examined at 8 and 16 weeks following implantation using radiography, micro-computed tomography, histology, and scanning electron microscopy.
Results: After AHIE treatment, average surface roughness increased marginally ( > 0.05) due to predominantly micron-scale with random nano-scale alterations, whereas wettability improved substantially ( < 0.05). In addition to micro/nano-scale defects, the AHIE treatment produced few honeycomb-like surface patterns. The AHIE implants demonstrated early and direct bone to implant body contact, and achieved stronger bone fixation in vivo than machined implants.
Conclusions: Based on laboratory and in vivo data, we conclude that AHIE processing of titanium implants may be a promising technique for improving surface quality while assuring secure and effective osseointegration for dental implant.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11703493 | PMC |
http://dx.doi.org/10.1080/17435889.2024.2435246 | DOI Listing |
J Spine Surg
December 2024
Surgical and Orthopaedic Research Laboratories, Prince of Wales Clinical School, University of New South Wales, Sydney, AUS.
Background: Implant fixation is often the cornerstone of musculoskeletal surgical procedures performed to provide bony fixation and/or fusion. The aim of this study was to evaluate how different design features and manufacturing methods influence implant osseointegration and mechanical properties associated with fixation in a standardized model in cancellous bone of adult sheep.
Methods: We evaluated the performance of three titanium alloy implants: (A) iFuse-TORQ implant; (B) Fenestrated Sacroiliac Device; and (C) Standard Cancellous Bone Screw in the cancellous bone of the distal femur and proximal tibia in 8 sheep.
ACS Nano
January 2025
Advanced Medical Research Institute, Cheeloo College of Medicine, Shandong University, Jinan 250012, P. R. China.
Blood-contacting medical devices can easily trigger immune responses, leading to thrombosis and hyperblastosis. Constructing microtexture that provides efficient antithrombotic and rapid reendothelialization performance on complex curved surfaces remains a pressing challenge. In this work, we present a robust and regular micronano binary texture on the titanium surface, characterized by exceptional mechanical strength and precisely controlled wettability to achieve excellent hemocompatibility.
View Article and Find Full Text PDFJ Mater Sci Mater Med
January 2025
Clinic of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hannover, Germany.
Although implants have undergone a remarkable development over the past decades, modern implants still show complications that make the improvement of materials necessary. The presented study investigates the load-bearing capacity of an experimental dental implant made of a niobium alloy (Nb1Zr) compared to identical implants made of Ti6Al4V using chewing simulation for artificial aging. Eight implants each with an experimental design were manufactured from Nb1Zr and Ti6Al4V.
View Article and Find Full Text PDFCurr Med Imaging
January 2025
Consultant in Emergency Medicine, WIC Clinic, Primary Health Care Corporation, Doha, Qatar.
Introduction: Pneumocephalus and pneumorrhachis are rare postoperative complications, commonly occurring within a few days to months after spinal surgery. They are very rarely reported after thoracic surgeries. This case highlights a unique presentation in the emergency department involving headache and vomiting caused by late complications following thoracic surgery with a titanium rib implant.
View Article and Find Full Text PDFClin Oral Investig
January 2025
Department of Oral Biology, University Clinic of Dentistry, Medical University of Vienna, 1090, Vienna, Austria.
Objective: Titanium surface modifications improve osseointegration in dental and orthopedic implants. However, soft tissue cells can also reach the implant surface in immediate loading protocols. While previous research focused on osteogenic cells, the early response of soft tissue cells still needs to be better understood.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!