Tips versus Holes: ×10 Higher Scattering in FIB-made Plasmonic Nanoscale Arrays for Spectral Imaging.

ACS Omega

Advanced Laboratory of Electro-Optics (ALEO), Department of Applied Physics/Electro-Optics Engineering, Lev Academic Center, Jerusalem 9116001, Israel.

Published: November 2024

Plasmonic nanostructure arrays, designed for performance as pixels in an advanced SERS imaging device, were fabricated by gallium focused ion beam (FIB). Though the FIB is best suited for etching holes and negative structures, our previously reported simulations favor protrusions. Herein, we report on the FIB methodology to "sculpt" positive structures by "ion-blasting" away the surrounding material. Nanoprotrusions and nanoholes with different aspect ratios are compared experimentally with depth and height controlled by the dwell time. The amplitude and spectra of optical absorption and scattering from the two species are compared as a function of structure height. Measurements were performed using ASI's model Rainbow hyperspectral camera, demonstrating the utility of hyperspectral microscopy for plasmonic imaging applications. Both the scattered and absorbed radiation display the broad peak qualitatively similar to the localized surface plasmon (LSP) scattering spectrum of gold nanospheroids. The intensity of the scattered light from the protrusions-measured in dark-field-was observed to be an order of magnitude higher than that from the nanoholes, consistent with simulation predictions. Poor contrast against bright background specular reflection is inherent in bright-field reflection mode; image-processing succeeded in detecting patterns indiscernible to the eye. To extract the absorption the full hyperspectral image field was exploited, allowing the sample to serve as its own reference. The resulting spectra display a plasmonic resonance which grows stronger and increasingly red-shifted at increasing heights, corroborating visual observations of changes in sample hue.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11603395PMC
http://dx.doi.org/10.1021/acsomega.4c04775DOI Listing

Publication Analysis

Top Keywords

tips versus
4
versus holes
4
holes ×10
4
×10 higher
4
higher scattering
4
scattering fib-made
4
plasmonic
4
fib-made plasmonic
4
plasmonic nanoscale
4
nanoscale arrays
4

Similar Publications

Background: Due to its complexity and multimodality treatment needs, traditional delivery of head and neck cancer care often occurs in a multidisciplinary cancer center, frequently in a university-based program in an urban setting. Fellowship training opportunities for subspecialty-focused head and neck surgeons have increased over recent years. There is a persistent concern that the number of newly minted Head & Neck Surgeons graduating each year outpaces the number of university-based employment opportunities, and that the workforce does not match the job opportunities.

View Article and Find Full Text PDF

Background: Unicompartmental knee arthroplasty (UKA) procedures have become much more common in the United States in recent years, with >40,000 UKAs performed annually. However, it is estimated that 10% to 40% of UKAs fail and thus require conversion to total knee arthroplasty (TKA). In the field of total joint arthroplasty, robotic-assisted surgeries have demonstrated advantages such as better accuracy and precision of implant positioning and improved restoration of a neutral mechanical axis.

View Article and Find Full Text PDF

Temporary Circular External Fixation for Spanning the Traumatized Ankle Joint.

JBJS Essent Surg Tech

December 2024

Division of Orthopaedic Surgery, Department of Surgical Sciences, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa.

Background: Temporary ankle-spanning circular fixation aims to provide osseous stability while (1) allowing access to and recovery of the traumatized soft-tissue envelope and (2) facilitating safe, comfortable, and clinically relevant cross-sectional imaging for surgical planning. It is most commonly utilized in a "span-scan-plan" treatment strategy in cases of peri-articular fractures around the ankle. Conventional monolateral fixators are prone to morbidity at the half-pin sites in the foot and variation in construct stability.

View Article and Find Full Text PDF

Far Posterior Approach for Rib Fracture Fixation: Surgical Technique and Tips.

JBJS Essent Surg Tech

December 2024

Department of Orthopedics, OhioHealth Health System, Columbus, Ohio.

Article Synopsis
  • The video article discusses the far posterior or paraspinal approach for treating posterior rib fractures, which enhances intraoperative visibility and minimizes muscle damage.
  • This method helps preserve periscapular strength, achieving up to 95% recovery six months after surgery through muscle-sparing techniques.
  • The surgical process involves precise skin incision and careful dissection of muscles like the trapezius, rhomboids, and latissimus dorsi to allow for effective access and treatment of the fractures without significant tissue loss.
View Article and Find Full Text PDF

Tips versus Holes: ×10 Higher Scattering in FIB-made Plasmonic Nanoscale Arrays for Spectral Imaging.

ACS Omega

November 2024

Advanced Laboratory of Electro-Optics (ALEO), Department of Applied Physics/Electro-Optics Engineering, Lev Academic Center, Jerusalem 9116001, Israel.

Plasmonic nanostructure arrays, designed for performance as pixels in an advanced SERS imaging device, were fabricated by gallium focused ion beam (FIB). Though the FIB is best suited for etching holes and negative structures, our previously reported simulations favor protrusions. Herein, we report on the FIB methodology to "sculpt" positive structures by "ion-blasting" away the surrounding material.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!