Adeno-associated virus-based gene therapy is a promising avenue in heart failure treatment, but has shown limited cardiac virus uptake in humans, requiring new approaches for clinical translation. Using a Yorkshire swine ischemic heart failure model, we demonstrate significant improvement in gene uptake with temporary coronary occlusions assisted by mechanical circulatory support. We first show that mechanical support during coronary artery occlusions prevents hemodynamic deterioration (n = 5 female). Subsequent experiments show that coronary artery occlusions during gene delivery improve gene transduction, while adding coronary sinus occlusion (Stop-flow) further improves gene expression up to >1 million-fold relative to conventional intracoronary infusion. Complete survival during and after delivery (n = 10 female, n = 10 male) further indicates safety of the approach. Improved cardiac gene expression correlates with virus uptake without an increase in extra-cardiac expression. Stop-flow delivery of virus-sized gold nanoparticles exhibits enhanced endothelial adherence and uptake, suggesting a mechanism independent of virus biology. Together, utilizing mechanical support for cardiac gene delivery offers a clinically-applicable strategy for heart failure-targeted therapies.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11609281 | PMC |
http://dx.doi.org/10.1038/s41467-024-54635-x | DOI Listing |
Comput Methods Biomech Biomed Engin
February 2025
Zhejiang Weilian Technology Co., Ltd, Jiaxing, China.
Functional and esthetic results require accurate implant placement. We aimed to develop a predictive method for assessing dental implant accuracy, and to evaluate the cumulative system influence of surgical guides. A mathematical model was constructed to determine the influence of surface changes on a specific point, using Jacobian matrix expressions.
View Article and Find Full Text PDFCurr Opin Crit Care
January 2025
Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, University of Milan, Milan, Italy.
Purpose Of Review: The increasing use of prone position, in intubated patients with acute respiratory distress syndrome as well as in patients with acute hypoxemic respiratory failure receiving noninvasive respiratory support, mandates a better definition and monitoring of the response to the manoeuvre. This review will first discuss the definition of the response to prone positioning, which is still largely based on its effect on oxygenation. We will then address monitoring respiratory and hemodynamic responses to prone positioning in intubated patients.
View Article and Find Full Text PDFDiscov Nano
January 2025
National Nanotechnology Laboratory for Agriculture (LNNA), Embrapa Instrumentação, 1452 XV de Novembro St., São Carlos, SP, 13560-970, Brazil.
Multifunctional membranes applied to biomedical materials become attractive to support the biological agents and increase their properties. In this study, biopolymeric fibers based on polycaprolactone (PCL) and pectin (PEC) were reinforced with faujasite zeolite (FAU) for cloxacillin antibiotic (CLX) loading. FAU with a high specific surface area (347 ± 8 m g), high crystallinity and particles with a diameter of up to 100 nm were produced under optimized synthesis conditions (100 °C/4 h).
View Article and Find Full Text PDFHeliyon
January 2025
BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Australia.
Breast-conserving surgery accompanied by adjuvant radiotherapy is the standard of care for patients with early-stage breast cancer. However, re-excision is reported in 20-30 % of cases, largely because of close or involved tumor margins in the specimen. Several intraoperative tumor margin assessment techniques have been proposed to overcome this issue, however, none have been widely adopted.
View Article and Find Full Text PDFHeliyon
January 2025
Department of Ultrasound Medicine, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, 210008, People's Republic of China.
Objectives: This study aimed to establish standard transesophageal echocardiographic (TEE) measurements of left ventricular (LV) morphology, function, and myocardial work parameters in healthy Beagle dogs using pressure-strain loops (PSL). Additionally, it sought to standardize optimal TEE imaging techniques and explore the potiential application of myocardial work analyis in veterinary medicine.
Methods: Thirty-seven healthy male Beagle dogs were anesthetized, intubated, and mechanically ventilated for TEE examinations.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!